Product Specifications and
Operations Manual
ELT160.60.100-07NC
Transparent Matrix Display
Beneq Oy
Olarinluoma 9
Tel. +358 9 7599 530
VAT ID FI25115461
FI-02200 Espoo
Fax +358 9 7599 5310
www.beneq.com
Finland
www.lumineq.com
Date: October 7, 2019
Document number: ED001129C
Page | 10
Figure 1. Video input timing diagram
Table 4. Timing restrictions
Description
Symbol Minimum value (ns)
SCLK high time
T
CH
100
SCLK low time
T
CL
100
SS -> SCLK setup time
T
SS
100
SCLK -> SS hold time
T
SH
100
SS disabled between cycles
T
SW
100
Data setup time
T
DS
100
Data hold time
T
DH
100
3.4.2
Initial Power-up