5.10.9 MOUNT OVERPRESSURE VALVE
Position the overpressure valve (1) and valve (2).
Tighten.
25 N·m 2.5 Kg-m + LOCTITE 243
®
5.10.10 MOUNT OIL SUMP
ATTENTION:
Always use new gaskets or O-rings.
Position the two centering dowels on the base.
Position the O-Ring (1) on the casing.
Apply the gasket onto the casing surface.
Remount the oil drip filter fixing the two screws (2) and
tightening them.
10 N·M 1Kg-m + LOCTITE 243
®
Position the sump (2) and tighten the magnetic screw cap
(3).
22 N·m 2.2 Kg-m
Tighten according to the order indicated in the figure.
10 N·m 1 Kg-m
Summary of Contents for TnT1130
Page 1: ......
Page 39: ...UK 39 MF13 S S S Ls Ls DRY NEW NEW NEW NEW L ...
Page 40: ...UK 40 MF13 ...
Page 41: ...UK 41 MF13 ...
Page 42: ...UK 42 MF13 R L L E E E ...
Page 43: ...UK 43 MF13 ...
Page 44: ...UK 44 MF13 Ls L R E NEW L R E E E L E E L E ...
Page 45: ...UK 45 MF13 Ls L E L E Ls ...
Page 46: ...UK 46 MF13 E E T T T T T L Ls ...
Page 47: ...UK 47 MF13 E E E E E E ...
Page 48: ...UK 48 MF13 ...
Page 49: ...UK 49 MF13 ...
Page 50: ...UK 50 MF13 ...
Page 51: ...UK 51 MF13 L E E L L ...
Page 113: ...UK 113 MF13 ...
Page 121: ...UK 121 MF13 ...
Page 192: ...UK 192 MF13 Remove the five screws 6 Remove screw 7 Remove the two screws 8 ...
Page 193: ...UK 193 MF13 Remove screw 9 Remove the two screws 10 Loosen and remove screw 11 ...
Page 199: ...UK 199 MF13 Remove the toothed wheel 2 Remove the roller cage 3 Remove the screws 4 ...
Page 243: ...UK 243 MF13 ...
Page 317: ...UK 317 MF13 ...
Page 318: ...UK 318 MF13 E E E E Electrical P P P P Plant 9 ELECTRICAL PLANT ...
Page 339: ...UK 339 MF13 ...
Page 391: ...UK 391 MF13 ...
Page 392: ...Produced and Printed SERIART Fabriano AN ITALY ...