Settings
Settings
isoNAV685-D_D00215_02_M_XXEN/04.2017
36
10.1
(5.3.2.2) IP
Set the appropriate IP address for the ISOMETER®.
10.1
(5.3.2.3) SN
Set the appropriate subnet mask.
10.1
(5.3.2.4) Std. GW
If a standard gateway is used, enter the IP address here.
10.1
(5.3.2.5) DNS server
If a DNS server is used, enter the server's IP address.
Contact your network administrator in case you have questions about the configuration
of the DNS server.
10.1
(5.3.2.6) Domain
Enter the domain.
Contact your network administrator in case you have questions about the configuration
of the domain.
10.1
(5.3.3) BCOM
Set the parameters for communication with other devices via BCOM.
For further information, refer to
10.1
(5.3.3.1) System name
Set the system name of the network in which the devices are located. In order to guaran-
tee that all devices are able to communicate via BCOM, all devices must have the same
system name.
10.1
(5.3.3.2) Subsystem
Configure the subsystem address of the network in which the devices are located. The de-
vices can communicate with subsystems with the same or different subsystem addresses.
10.1
(5.3.3.3) Device address
Assign a device address. Each device must have a different address to distinguish it from
another in the system and ensure correct communication.
10.1
(5.3.3.4) Timeout
Set the timeout for messages between 100 ms…10 s.
This time specification defines the maximum permissible time for a device to respond.
10.1
(5.3.3.5) TTL for subscription
Set a time between 1 s…1092 min.
This time defines the intervals at which the ISOMETER® sends messages to e.g. a gateway.
Severe alarms (e.g. insulation alarms or substantial value changes) are always sent imme-
diately.
10.1
(5.3.4) Modbus TCP
Settings for communication with other devices via Modbus TCP.
For further information, refer to
.
10.1
(5.3.4.1) Port 502
Choose whether Modbus TCP should be used:
10.1
(5.3.5) BMS
10.1
(5.4) Display
Adjust the display brightness for the ISOMETER® in the display menu:
10.1
(5.4.1) Brightness
Adjust the display brightness between 0 % and 100 % in steps of 10.
If no button is pressed on the display for 15 minutes, the brightness of the display is re-
duced. If now a button is pressed, the normal brightness is restored.
10.1
(5.5) Password
Use the password function to protect the device parameters against unauthorised adjust-
ment. The default password is 0000.
10.1
(5.5.1) Password
Enter an individual four-digit password.
•on
Modbus TCP can be used for communication with other devices.
•off
Modbus TCP cannot be used for communication with other devices.
The function of the BMS bus is not available in this device.