Commissioning
5.5
Appliances with optional plug-in
diverter valve: Setting hot water
temperature
B
Set the hot water temperature by means of the tem-
perature control
on the appliance.
Fig. 36
ECO button
Pressing and holding the ECO button
switches from
Comfort mode
to
ECO-mode.
Comfort mode, ECO button is not lit (factory set-
ting)
Comfort mode the hot water tank has priority. The hot
water cylinder is first heated up to the set temperature.
The appliance then switches to central heating mode.
ECO mode, button is lit
In ECO mode the appliance switches between central
heating mode and cylinder charging mode every
12 minutes.
5.6
Frost protection
The appliance has an in-built frost protection device
which is generally suitable for most applications.
B
Leave master switch switched on.
If the appliance is to be left for long periods switch the
central heating off:
B
Add a suitable anti-freeze fluid to the water in the
central heating system.
Suitable products are available from Betz-Dearborn
Tel: 0151-4209563 and Fernox Tel: 01799-
550811.
5.7
Pump anti-seize function
Every time the pump is switched off, a timer is started.
If after 24 hours the pump has not run again, it is
switched on for a period of 5 minutes.
5.8
Fault Condition
In the unlikely event of a fault occurring while the appli-
ance is in operation:
The display then shows a fault code and the button
may also flash.
If the button
flashes:
B
Press and hold the button
until the display shows
“
– –
”.
The appliance will then start up again and the display
will show the central heating flow temperature.
If the button
does not flash:
B
Switch the appliance off and then on again at the
master switch.
The appliance will start up again and the central heat-
ing flow temperature will be displayed.
B
Do not set the temperature higher than
60°C for normal operation.
B
Only use temperatures of up to 70°C
temporarily for thermal disinfection pur-
poses.
Control Setting
Water Temperature
Anti-clockwise limit
approx. 10°C
(frost protection)
!
approx. 60°C
Clockwise limit
approx. 70°C
Table 11
6 720 610 333-07.1O
i
This function prevents the central heating
pump seizing after long periods of inactiv-
ity.
i
A list of faults that may occur is given on
page 42.