Installation
3.4
Wall mounting frame assembly
B
Take the wall mounting frame out of the package and
screw together with 6 screws as shown in fig. 9. Use
the inner lugs on the top and bottom horizontal sec-
tions.
Fig. 9
B
Hold the wall-mounting frame against the wall ensur-
ing that it is vertical.
B
Mark the holes for the wall mounting frame onto the
wall, drill and plug the holes and screw the wall
mounting frame to the wall with the screws provided.
B
Mark the position of the flue duct hole if a rear flue is
to be used. Refer to fig. 1 and 18.
Fig. 10
B
Screw the pre-plumbing manifold with two screws to
the wall mounting frame.
Fig. 11
3.5
Pre-piping the system
Fig. 12 Manifold
43
CH flow
47
CH return
112
Gas cock
171
Optional cylinder flow (used only with motorised valve)
172
Optional cylinder return (used only with motorised valve)
B
A drain tap should be fitted at the lowest point of the
central heating system.
B
WRAS approved filling loop must be fitted.
6 720 610 576-04.1O
6 720 610 576-05.1O
6 720 610 576-11.1O