42
8.4 IEE Command Set
1.
Capacity <01>
Not available.
2.
Display Firmware Version <02>
Display software checksum and software number.
3.
Read cursor <03>
Not available.
4.
Read data <04>
Not available.
5.
Begin blink <06>
Begin blink field at current cursor location.
6.
End blink <07>
End blink field at current cursor location.
7.
Backspace <08>
Backspace cursor location one position (cursor stays when at home location).
8.
Advance cursor <09>
Advance cursor location one position (cursor wraps around after bottom right character
location).
9.
Line Feed <0A>
Line feed (vertical scroll from bottom line; cursor position does not change).
10.
Clear the display <0C>
Clear the display (cursor stays).
11.
Carriage Return <0D>
Return cursor to left-most character position of the same line, but do not clear display.
12.
Make cursor invisible <0E>
Make cursor indicator invisible. The cursor location counter continues to function but
there is no visible indicator of next character location.
13.
Make cursor visible <0F>
Make cursor indicator visible, flashing block. Default mode.
14.
Automatic Carriage Return & Line Feed <10>
Bottom line data entry with automatic carriage return & line feed. Puts cursor at left side
bottom row and data enters beginning at the left-most character. Position of the bottom
row, vertical scroll from bottom line after line has been filled.