Connecting to the Gas Supply
9
This area to be clear of pipework
and obstructions
450
250
8
0
470
1085
570
160
60
MAINS INLET ON
APPLIANCE
Connection to the cooker should be made with an approved appliance flexible connection
to BS 669. Hoses connected to the LPG models should be suitable for LPG and capable of
withstanding 50mbar pressure. A length of 0.9 to 1.25m is recommended. The length of
hose chosen should be such that when the cooker is in situ, the hose does not touch the
floor.
The temperature rise of areas at the rear of the cooker that are likely to come in contact
with the flexible hose do not exceed 70˚C.
After installation, check for soundness.
The supply pressure can be checked at the grill injector. Access to the injector is by first
removing the baffle at the front of the grill compartment and then the burner.
The cooker is designed to match the depth of
standard 600mm worktops. An adaptor backplate
should, therefore, be fitted within the 160 x
250mm shaded area shown, pointing towards the
left to allow the cooker to be pushed fully to the
wall. If a forward facing backplate is used, it must
be chased into the wall.
Summary of Contents for Cookcenter 131