PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
4.14
A
30” and 36” Wide, Distinctive Series
Slide-in Gas Cooktops
DRT304S, DRT366S
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
1.0 Amp @ 120 Vac, 60 Hz
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
Installation of a non-combustible material* (up to the hood) or a backsplash
is always recommended, and mandatory if the distance to the back
wall from the cooktop is less than 2 1/2” (Figure 2). When installing
a backguard, use only Dacor model numbers AEB3009, AEB3012
(DRT304S), AEB3609 or AEB3612 (DRT366S).
SIDE VIEW WIThoUT BACkGUARD
SIDE VIEW WIThoUT BACkGUARD
SIDE VIEW
Product Dimensions
Electrical and Gas Supply Requirements
Cabinet and Countertop Layout
COOKTOP WIDTH (A)
DRT304S
29 7/8” (759 mm)
DRT366S
35 7/8” (911 mm)
Product tolerances:
±1/16” (±1.6 mm)
unless otherwise noted
WARNING
Observe all governing codes and ordinances during planning
•
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
•
accompanying installation instructions.
Document # PG04 - 003
Revised 02/16/10 Page 1/3
4” (102 mm)
5/8” Min.
(16 mm)
7 3/4”
(197 mm)
Trim:
1/2”
(13 mm)
thick
25 7/8” (657 mm)
1 5/8” (41 mm) cooking surface
height (grate level) above
countertop
3/4” gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2” (51 mm) from chassis bottom
28 1/8” (714 mm)
Power cord
32” long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (64 mm) Min. to
combustible rear wall