80
Bell
fi res
English
Instructions for use and installation instructions
Important:
Ensure that the correct fl ue gas restriction plate is mounted.
Use of the correct fl ue gas restriction plate will provide
optimum effi ciency, fl ame effect and combustion. Mounting
an incorrect fl ue gas restriction plate can result in damage
to the gas fi re.
Figure 31: Positioning restriction plate
The following restriction plates are supplied:
Restriction plate:
Width: B = 30 mm
Width: B = 40 mm
Width: B = 50 mm
Width: B = 65 mm
Width: B = 80 mm
3.7.7 Checking the appliance following installation
After installation, visually check the gas fl ame. When the fi re is ignited, the fl ames
should be short and blue/yellow in colour. These fl ames should gradually increase in
height and become more yellow. When all fl ames are yellow, the gas fi re has reached
the correct temperature.
THE GAS FIRE IS NOW READY FOR USE
!"
#"
$
%&%'()*
Assembly