VFM-60
Vortex Flowmeter
Rev1.3
Date:24/04/2020 User’s Manual
49 / 59
□
Temperature range
Low temperature version
180 ~100
−
℃
℃
Normal temperature version
40 ~150
−
℃
℃
Medium temperature version
40 ~250
−
℃
℃
High temperature version
40 ~350
−
℃
℃
□
Pressure range
Available pressure rating includes 1.6Mpa, 2.5Mpa, 4.0Mpa, 6.4Mpa. If the application requires a
higher-pressure rating, please contact us to check the possibility.
Size and dimension
□
Size and dimension for wafer type
VFM60N Wafer type 150 dgrC version
VFM60N Wafer type 250/350 dgrC version
Size
K
(Pipe
O/D)
L
(Pipe
length)
W
(Flange
screwhole
distance)
C (flange
thickness)
m
(screwhole
diameter)
n
(screw
qty)
H (Meter
height)
150dgrC
H (Meter
height)
250dgrC
H (Meter
height)
350dgrC
Flange
O/D
15
75
65
100
18
14
4
294
335
475
130
20
75
65
100
18
14
4
294
335
475
130
25
75
65
100
18
14
4
288.5
329.5
469.5
130
32
80
65
120
20
14
4
292.8
333.8
473.8
145
40
84
65
120
20
14
4
295.8
336.8
476.8
145
50
94
65
132
22
18
4
301
342
482
160
65
105
65
144
24
18
6
308.5
349.5
489.5
180