VFM-60
Vortex Flowmeter
Rev1.3
Date:24/04/2020 User’s Manual
21 / 59
Picture Enter or quit digital setting
When in digital setting, the first row will display the reference number of the digital setting, and
the lower row will display the contents of this parameter. The digit that is flashing is the digit under
setting. Please reference to picture 5.4., which means D001=1.60000, max pressure is 1.6 (unit
according to other setting.)
Picture 5.4 digital setting
When under digital setting, Now, user can use “L-R button” to choose which digit on the displayer
are to be set , and use “R-D button” to switch the digit to 0~9 . The first time of pressing “Enter
button” means to set the lower row. Press “Enter button” again to check if the setting is available. If
setting is available, the setting made will be canceled and the display will not flash, then press “L-R
button” or “U-D button” to set again. When display is not flashing, pressure “Enter button” to save
and go to next setting.
If want to quit code setting, same as entering, please hold “Enter button” then press “U-D button”
at the same time.
5.2 Setting list
Please check chart 5.1 and 5.2 for code and digital setting address list.
Chart 5.1 Code setting address