DCP Site Configuration Procedure:
The DCP must be configured with the specific information for the destination airport.
Access the WEB site WWW.airnav.com and enter the specific airport designator for the
destination airport. Print the complete package of information for the airport. When the
configuration is completed, staple the complete Air Nav Document to the Comprehensive
Facility Performance and Adjustment Form.
1.
In the DCP Power Enclosure, turn off AC power by turning off circuit breaker 1.
2.
In the DCP Power Enclosure, turn off DC power by turning off circuit breaker 2.
3.
Lower the tower to gain access to the bad DCP.
4.
Remove the four mounting screws holding the Bad DCP to the tower.
5.
Disconnect all cable connectors from the unit. Note the locations of the cable connectors
when connected to the DCP.
6.
Connect the cables to the new DCP.
7.
Re-install the four mounting screws to hold the new DCP to the tower.
8.
Connect the PC to the DCP cable dongle in the DCP Power Enclosure.
9.
On the PC, open a DOS window and browse to the TXCOM program for the version of
DCP program in the UUT. Start the TXCOM program as follows:
Enter “acbstxcom108A comx”<cr>.
Acbstxcom108A is the revision for DCP’s with firmware code version 1.05D, and comx
(com1-com8) is the serial port as configured on the PC to be used for testing.
10.
The TXCOM program will respond with a hyphen (“-“) prompt.
11.
In the DCP Power Enclosure, turn ON AC power by turning on circuit breaker 1.
12.
Immediately enter on the PC, the monitor command by entering “m” <cr>.
13.
If the unit responds with an “Enter Password” message, enter the default password
“XXXXXXXXX”, <cr>.
Summary of Contents for AWOS
Page 17: ... 14 BELFORT INSTRUMENT Proprietary Information Figure 2a Securing the Tower for Maintenance ...
Page 49: ... 46 BELFORT INSTRUMENT Proprietary Information Figure 9 Temperature Humidity Sensor Removal ...
Page 51: ... 48 BELFORT INSTRUMENT Proprietary Information Figure 10 Visibility Sensor Removal ...
Page 60: ...BELFORT INSTRUMENT Proprietary Information Appendix A Belfort AWOS Maintenance Forms ...
Page 66: ...BELFORT INSTRUMENT Proprietary Information This page intentionally left blank ...
Page 74: ...BELFORT INSTRUMENT Proprietary Information Appendix C UHF Transceiver Specifications ...
Page 88: ...BELFORT INSTRUMENT Proprietary Information Appendix F DCP Site Configuration Procedure ...