15.
When the pointer is properly aligned, use the small screw driver to loosen the set screws
on the vane shaft. Remove the vane.
16.
Position the new vane on the direction shaft and tighten the set screws.
17.
Use the rubber band to secure the vane as shown in Figure 4.
18.
Go to step 11 of this procedure and follow instructions.
Figure 12
Wind Direction Sensor Removal