Tofino Xenon Security Appliance Tofino SA
Release 06 09/2018
33
2.4.1
Connecting the power supply and the signal contact
lines
Supply voltage
The supply voltage can be connected redundantly. Both inputs are
uncoupled. There is no distributed load. With redundant supply, the power
supply unit with the higher output voltage supplies the device on its own.
The supply voltage is electrically isolated from the housing.
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires connected by tightening the terminal screws.
Signal contact (optional)
Connect the wires according to the pin assignment on the device with
the clamps.
Fasten the wires connected by tightening the terminal screws.
1
Supply voltage connection 1
1a
24 V
1b
0 V
2
Connection for the signal contact
3
Supply voltage connection 2
3a
0 V
3b
24 V
Table 9:
Pin assignment: 6 pin, screwable terminal block (on the top), connection
to the device (at the bottom)
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment on the device
DC voltage
Rated voltage range DC:
12 V DC ... 48 V DC
Voltage range DC incl.
maximum tolerances:
9.6 V DC ... 60 V DC
24 V Plus terminal of the supply voltage
0 V Minus terminal of the supply
voltage
AC voltage
Rated voltage AC:
24 V AC
Voltage range AC incl.
maximum tolerances:
18 V ... 30 V
24 V Outer conductor
0 V Neutral conductor
Table 10: Type and specification of the supply voltage, pin assignment on the
device
1a
1b
2
2
3a
3b
Summary of Contents for Tofino Xenon