Tofino Xen
on Securit
y App
liance To
fin
o
SA
Release
06
0
9/2018
45
EN 61000-6-4
AC and DC supply connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EN 55032
Telecommunication connections
Class A
Class A
Class A
Class A
EN 61000-6-4
Telecommunication connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EMC interference
immunity
Standard
applications
Navy applications Railway
applications
(trackside)
Substation
applications
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
±4 kV
±6 kV
±6 kV
±8 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
±8 kV
±8 kV
±8 kV
±15 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 3000 MHz
10 V/m
10 V/m
20 V/m
10 V/m
IEEE 1613
80 MHz ... 1000 MHz
—
—
—
35 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
AC/DC supply connection
±2 kV
±2 kV
±2 kV
±4 kV
EN 61000-4-4
IEEE C37.90.1
Data line
±4 kV
±4 kV
±4 kV
±4 kV
Voltage surges - DC supply connection
EN 61000-4-5
line/ground
±2 kV
±2 kV
±2 kV
±2 kV
IEEE 1613
line/ground
—
—
—
±5 kV
EN 61000-4-5
line/line
±1 kV
±1 kV
±1 kV
±1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
±1 kV
±1 kV
±2 kV
±4 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
10 V
10 V
EMC interference
emission
Standard
applications
Navy applications Railway
applications
(trackside)
Substation
applications