36
Installation MACH104-PoEP
Release 06 11/2013
PoE power
Maximum number of Powered
Devices (PDs)
8 × Powered Device (PD) class 4 (30 W)
16 × Powered Device (PD) class 0
(15.4 W)
Power failure
bypass
MACH104-16TX-PoEP...
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-
R...
> 20 ms
MACH104-16TX-PoEP-E...
MACH104-16TX-PoEP+2X-
E...
> 10 ms
Note:
Applies to the basic device only,
not
to the Powered Devices connected.
Overload current
protection at input
Non-replaceable fuse
Climatic conditions
during operation
Ambient temperature
+32 °F ... +122 °F (0 °C ... +50 °C)
Note:
This applies to the following device
variants only:
MACH104-16TX-PoEP+2X...
MACH104-16TX-PoEP+2X-R...
MACH104-16TX-PoEP+2X-E...
If XFP transceivers without extension
“EEC” are used, the maximum operating
temperature is reduced to 40 °C. For
operating temperatures between 40 °C
and 50 °C, use M-XFP...EEC transceivers.
Humidity
10% ... 95%
(non-condensing)
Air pressure
minimum 795 hPa (+2000 m)
maximum 1060 hPa (
≈
−
1312 ft (
−
400 m))
Climatic conditions
during storage
Ambient temperature
−
4 °F ... +185 °F (
−
20 °C ...+85 °C)
Humidity
10% ... 95%
(non-condensing)
Air pressure
minimum 700 hPa (
≈
+9842 ft (+3000 m))
maximum 1060 hPa (
≈
−
1312 ft (
−
400 m))
Signal contact
Switching current
max. 1 A, SELV
Switching voltage
max. 60 V DC or max. 30 V AC, SELV
Pollution degree
2
Protection classes Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP 30