![Belden Hirschmann MACH104-16TX-PoEP Series User Manual Download Page 15](http://html.mh-extra.com/html/belden/hirschmann-mach104-16tx-poep-series/hirschmann-mach104-16tx-poep-series_user-manual_2725669015.webp)
Installation MACH104-PoEP
Release 06 11/2013
15
1.5.1
MACH104-16TX-PoEP...
MACH104-16TX-PoEP+2X...
For the supply voltage, the following applies:
A power module providing the PoE voltage and the internal supply voltage
is integrated in the device.
Supply voltage is connected via a non-heating appliance socket.
The input voltage is electrically isolated from the housing.
1.5.2
MACH104-16TX-PoEP-R...
MACH104-16TX-PoEP+2X-R...
For the supply voltage, the following applies:
The supply voltage can be connected redundantly.
Two power modules providing the PoE voltage and the internal supply
voltage are integrated in the device. The power modules operate in load-
sharing mode.
Supply voltage is connected via non-heating appliance sockets.
The input voltage is electrically isolated from the housing.
Both inputs are separate from one another.
Note:
With non-redundant supply of the mains voltage, the device reports a
power failure. You can prevent this message by applying the supply voltage
via both inputs, or by changing the configuration in the Management.
1.5.3
MACH104-16TX-PoEP-E...
MACH104-16TX-PoEP+2X-E...
For the supply voltage, the following applies:
PoE voltage and internal supply voltage are provided by an external
power module.
The voltage supply is connected via a 3-pin terminal block with snap
locks.
You will find further information under
MACH104-16TX-PoEP+2X-E...: Wiring and assembling the operating
voltage” on page 24
1.6
Ethernet ports
You can connect terminal devices and other segments on the ports of the
device via twisted pair cables or F/O cables.
1.6.1
10/100/1000 Mbit/s twisted pair port
This port is an RJ45 socket.