Installation BAT867-R
Release 10 09/2021
33
Relevant for North America for power supply via a 2-pin terminal block:
The torque for tightening the supply voltage terminal block on the device is
0.51 Nm (4.5 lb-in).
Mount the terminal block on the device using screws.
By connecting the supply voltage via the terminal block, you start the
operation of the device.
2.6
Connecting data cables
Note the following general recommendations for data cable connections in
environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. To reduce inductive coupling, verify that the power
supply cables and data cables cross at a 90° angle.
Use shielded data cables for gigabit transmission via copper cables, for
example SF/UTP cables according to ISO/IEC 11801. Exclusively use
shielded data cables to meet EMC requirements according to EN 50121-
4 and marine applications.
Connect the data cables according to your requirements.