Installation BAT867-R
Release 10 09/2021
9
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
When installing antennas, observe the regulations of the country in
which you are operating the WLAN device with regard to the general
operating permission and the maximum emission levels.
Install and operate this equipment with a minimum distance of 50 cm
(19.7 in) between the antenna and your body.
Grounding the device
For the functional earth (FE), there is a separate functional earth screw on
top of the device. The functional earth is electrically connected to the
circuit ground and the metal housing of the device.
Shielding ground
The overall shield of a connected shielded twisted pair cable is connected
to the grounding connector on the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.