Installation BAT450-F
Release 12 07/2020
81
13.6
EMC
13.7
Immunity
EGSM 900 CS
+32 dBm ±1 dB
GMSK mode, connectorized
(Class 4; 2 W, 33 dBm)
+27 dBm ±1 dB
8PSK mode, connectorized
(Class E2; 0.5 W, 27 dBm)
EMC interference
immunity
EN 61000-4-2
Electrostatic discharge
Contact discharge, test level 3
6 kV
Air discharge, test level 3
8 kV
EN 61000-4-3
Electromagnetic field
80 MHz ... 3000 MHz
max. 20 V/m
3000 MHz ... 6000 MHz
3 V/m
EN 61000-4-4
Fast transients (burst), test level 4
Power line
2 kV
Data line
4 kV
EN 61000-4-5
Voltage surges
Power line
line/line
1 kV
Power line
line/ground
2 kV
Data line: test level 3
2 kV
EN 61000-4-6
Conducted interference voltages, test level 3
150 kHz ... 80 MHz
10 V
EMC interference
emission
EN 55032
Class B
FCC 47 CFR Part 15
Class B
Immunity
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2
IEC 60068-2-64 test level in accordance with EN 50155
Shock
IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2,
EN 50155
Parameter
Conducted TX
(Transmit) power
tolerances
Notes
Table 36: Conducted TX power tolerances