Installation site requirements
During the installation, make sure that you adhere to the regulations of
the country in which you are operating the device.
In ambient temperatures under +14 °F (-10 °C), use cabling designed
for minimum temperatures.
Applies to device variants featuring supply voltage with characteristic
value N (110 V DC):
See “Device name and product code” on page 22.
Exclusively install this device in a restricted access location, to which
maintenance staff have exclusive access. Install the device in such a
way that it is protected against mechanical forces in the area of the
power supply.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Install the device in the vertical position, with the antenna connections
pointing upwards.
At ambient air temperatures > +140 °F (+60 °C):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Grounding the device
Grounding the device is by means of a separate ground connection on the
device.
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.