background image

FX FUSION SC CONNECTOR 

PX106500-EN  REV E 

Page 5 of 8 

900µm TIGHT BUFFER/250µm - INSTALLATION GUIDE

9.

  Strip the cable from that mark. 

  To avoid breaking the fiber, 

the buffer should be stripped 

about 5mm at a time.

IMPORTANT:

 When stripping, the 

buffer and the 250µm coating 

must be completely removed to 

allow to cleave the fiber.

10.

 Clean the fiber.

11.

  Cleave the fiber at 

10mm

For both Belden cleavers, the 

10mm

 mark is where the fiber 

holder ends as shown on red 

arrows.

 

 

 DON’T  TOUCH

 

OR

 attempt to

 

CLEAN

 the cleaved fiber.

Groove for 

250µm

Groove for 

900µm

Summary of Contents for FX FUSION SC CONNECTOR

Page 1: ...m TIGHT BUFFER 250 m INSTALLATION GUIDE Materials Fusion Splicer and Cleaver FX Fusion Splice On Installation Tool Kit FX Fusion Splice On SC Connector Kit FX Fusion Splice Holder FX Fusion Splice On...

Page 2: ...t creating activities Maintain the fiber components clean as your working area Clean end face with alcohol wipes and then dry wipe as cleaning procedures Instructions for Cleaver If the cleaver does n...

Page 3: ...lect the appropriate splicing mode based on fiber type SM or MM C If applicable remove the left fiber holder D Set the heating mode by referring to the heat setting table on the first page 2 Just befo...

Page 4: ...the fiber 5 Place the ferrule stub assembly in the FX Fusion splice holder and push it up to the position shown below NOTE It s recommended to remove the holder from splicer 6 Load the splice holder i...

Page 5: ...ld be stripped about 5mm at a time IMPORTANT When stripping the buffer and the 250 m coating must be completely removed to allow to cleave the fiber 10 Clean the fiber 11 Cleave the fiber at 10mm For...

Page 6: ...de of the fusion splicer NOTE The placement of the end face is important Fibers end face should be located in between the V groove and electrodes as shown 13 Perform the fusion 14 Bring the splice pro...

Page 7: ...d the ferrule stub assembly covered IMPORTANT The splice protection sleeve must completely cover the first portion of the ferrule stub assembly as shown below 17 Place the cable assembly into the spli...

Page 8: ...protection sleeve The round mark on the ferrule stub assembly must be aligned with the round mark of the front housing 20 Align the rear housing tabs with the front housing cutouts and snap the 2 part...

Reviews: