background image

FX FUSION SC CONNECTOR 

PX106500-EN  REV E 

Page 8 of 8 

900µm TIGHT BUFFER/250µm - INSTALLATION GUIDE

19.

  Bring the 

front housing

 close to 

the 

splice protection sleeve

The round mark on the 

ferrule 

stub assembly

 must be aligned 

with the round mark of the 

front 

housing

.

20.

  

Align the

 rear housing

 tabs 

with the 

front housing

 

cutouts 

and snap the 2 parts together

.

21.

   Align  the 

front

 and 

outer 

corners 

of both

 housings

 and 

snap the 2 parts together.

22.

  

Cut off the excess rod portion of 

the 

dust cap

.

Summary of Contents for FX FUSION SC CONNECTOR

Page 1: ...m TIGHT BUFFER 250 m INSTALLATION GUIDE Materials Fusion Splicer and Cleaver FX Fusion Splice On Installation Tool Kit FX Fusion Splice On SC Connector Kit FX Fusion Splice Holder FX Fusion Splice On...

Page 2: ...t creating activities Maintain the fiber components clean as your working area Clean end face with alcohol wipes and then dry wipe as cleaning procedures Instructions for Cleaver If the cleaver does n...

Page 3: ...lect the appropriate splicing mode based on fiber type SM or MM C If applicable remove the left fiber holder D Set the heating mode by referring to the heat setting table on the first page 2 Just befo...

Page 4: ...the fiber 5 Place the ferrule stub assembly in the FX Fusion splice holder and push it up to the position shown below NOTE It s recommended to remove the holder from splicer 6 Load the splice holder i...

Page 5: ...ld be stripped about 5mm at a time IMPORTANT When stripping the buffer and the 250 m coating must be completely removed to allow to cleave the fiber 10 Clean the fiber 11 Cleave the fiber at 10mm For...

Page 6: ...de of the fusion splicer NOTE The placement of the end face is important Fibers end face should be located in between the V groove and electrodes as shown 13 Perform the fusion 14 Bring the splice pro...

Page 7: ...d the ferrule stub assembly covered IMPORTANT The splice protection sleeve must completely cover the first portion of the ferrule stub assembly as shown below 17 Place the cable assembly into the spli...

Page 8: ...protection sleeve The round mark on the ferrule stub assembly must be aligned with the round mark of the front housing 20 Align the rear housing tabs with the front housing cutouts and snap the 2 part...