10.1 Safety instructions
Danger!
Supply voltage!
The contact with non-insulated parts carrying supply voltage involves the risk of an electric shock
resulting in severe injuries and death.
Measures:
•
Observe all regulations in effect during the electrical installation (e.g. VDE 0100)!
•
Any electrical works must only be carried out by authorised and skilled personnel.
•
The connection to the electric mains and the corresponding protective equipment must comply with
the legal provisions in force at the place of installation of the
METPOINT
®
BDL compact
; the con-
nection and installation must be carried out by skilled personnel who are qualified accordingly.
•
Make sure that no parts of the measuring devices are energised and that the measuring devices
cannot be connected with the electric supply mains during service measures.
Danger!
Missing earth connection!
When the earth connection (protective earth) is missing, there is the risk in the event of
malfunction, that contactable, conductive components may carry supply voltage. Touching
of such parts leads to an electric shock with injuries and death.
It is imperative to connect the plant to earth or to connect the protective conductor accord-
ing to the regulations.
Do not use plug adapters at the power plug.
Have the power plug replaced by qualified skilled persons, if required.
Danger!
Missing separator!
All voltages representing a hazard when coming into contact with them must be disconnect-
able via assigned separators that need to be installed externally.
The separator must be installed in the vicinity of the device.
The separator needs to correspond to IEC 60947-1 and IEC 60947-3.
The separator must separate all voltage-carrying conductors.
The separator must not be installed in the power supply line.
The separator must be easily accessible for the user.
Summary of Contents for METPOINT BDL compact
Page 15: ...Dimensions METPOINT BDL compact 15 Cutout for the mounting of the instrument panel ...
Page 83: ...Operation METPOINT BDL compact METPOINT BDL compact 83 Info Status ...
Page 84: ...Operation METPOINT BDL compact 84 METPOINT BDL compact Actual Values ...
Page 102: ...Declaration of conformity 102 METPOINT BDL compact 18 Declaration of conformity ...
Page 105: ...METPOINT BDL compact 105 ...
Page 106: ...METPOINT BDL compact ...
Page 107: ...METPOINT BDL compact 107 ...