Technical description
30
DRYPOINT® RA 1080-8800
11.15.4 Indication of a service warning
A service warning is an exceptional event and requires the attention of the operator/service technician. Such a warning
will usually not stop the dryer (unless a high dew point parameter was adjusted to stop the dryer).
When a service warning is active, the
LED flashes. When the service warning was automatically reset, it has been
stored and the
LED is continuously on.
In both cases the display shows the dew point temperature and the service warnings which are active or which are no
longer active but not yet reset.
Service warnings are not automatically reset (except for
which can be put on automatic reset).
To
RESET
the service warning,
simultaneously press the
log
reset
buttons for three seconds. Only the stored service
warning will be reset. Service warnings which are still active continue to be indicated by the flashing
LED.
NOTE: the operator/service technician must check the dryer and eliminate the problem that led to the
activation of the service warning.
Service warning
Description
PF1 – Probe 1 failure: failure temperature probe 1
PF2 - Probe 2 failure: failure temperature probe 2
PF3 - Probe 3 failure: failure temperature probe 3
HdP – High dew point: dew point too high, higher than the adjusted HdA value.
LdP – Low dew point: dew point too low
Setting T1< -1°C (30°F) delay five minutes / reset T1> 0°C (32°F)
drn - Drain: failure condensate drain (opening of the DRN contact – if an electronically level-
controlled condensate drain is installed – see electric diagram)
SrV - Service : maintenance service time expired SrV
dt – Outlet temperature: compressor outlet temperature (probe T4) outside the normal values
but within the safety limits
Setting T4> 90°C (194°F) delay three minutes / reset T4< 85°C (185°F)
HCP – High condensation pressure: condensation pressure (transformer HP) outside the
normal values but within the safety limits
Setting HP> 28barg (406psig) delay three minutes / reset HP< 25barg (363psig)
NOTE: when the dryer is switched on but no system pressure is applied, the
drain trouble indication may
appear.
Summary of Contents for DRYPOINT RA 1080-8800
Page 24: ...Technical data 24 DRYPOINT RA 1080 8800 10 2 Technical data DRYPOINT RA 1080 8800 3 460 60 ...
Page 42: ...Maintenance troubleshooting spare parts and dismantling 42 DRYPOINT RA 1080 8800 ...
Page 45: ...Appendices DRYPOINT RA 1080 8800 45 13 1 2 Dimensions DRYPOINT RA 2400 4400 ...
Page 46: ...Appendices 46 DRYPOINT RA 1080 8800 13 1 3 Dimensions DRYPOINT RA 5400 6600 ...
Page 47: ...Appendices DRYPOINT RA 1080 8800 47 13 1 4 Dimensions DRYPOINT RA 7200 8800 ...
Page 49: ...Appendices DRYPOINT RA 1080 8800 49 13 2 2 Exploded diagram DRYPOINT RA 1080 2200 AC ...
Page 50: ...Appendices 50 DRYPOINT RA 1080 8800 13 2 3 Exploded diagram DRYPOINT RA 2400 4400 AC ...
Page 51: ...Appendices DRYPOINT RA 1080 8800 51 13 2 4 Exploded diagram DRYPOINT RA 5400 6600 AC ...
Page 52: ...Appendices 52 DRYPOINT RA 1080 8800 13 2 5 Exploded diagram DRYPOINT RA 7200 8800 AC ...
Page 53: ...Appendices DRYPOINT RA 1080 8800 53 13 2 6 Exploded diagram DRYPOINT RA 1080 2200 WC ...
Page 54: ...Appendices 54 DRYPOINT RA 1080 8800 13 2 7 Exploded diagram DRYPOINT RA 2400 4400 WC ...
Page 55: ...Appendices DRYPOINT RA 1080 8800 55 13 2 8 Exploded diagram DRYPOINT RA 5400 6600 WC ...
Page 56: ...Appendices 56 DRYPOINT RA 1080 8800 13 2 9 Exploded diagram DRYPOINT RA 7200 8800 WC ...
Page 71: ...Appendices DRYPOINT RA 1080 8800 71 ...
Page 72: ...Appendices 72 DRYPOINT RA 1080 8800 ...
Page 73: ...Declaration of conformity CE DRYPOINT RA 1080 8800 73 14 Declaration of conformity CE ...
Page 74: ...Declaration of conformity CE 74 DRYPOINT RA 1080 8800 ...