Shutdown
Relieve the device from pressure!
Turn off power supply!
Have the device disconnected from power supply by a qualified electrician!
Remove all pipes and hoses from the device and loosen all fastenings for disassembly!
15.
Disposal
Observe the disposal instructions of the lubricant manufacturer when lubricant is changed! Lubricants
or cloths contaminated with lubricant or similar must be collected in specially marked receptacles and
disposed of accordingly.
Disposal of the device must be done properly and professionally and according to the national and
international laws and regulations.
Moreover, BEKA devices could contain batteries. Professionally and properly disposed batteries will
be recycled. They contain important raw materials.
16.
Troubleshooting
Malfunction
Possible cause
Possible remedy
Pump supplies
lubricant
Reservoir empty
Exchange barrel
Air inclusions in lubricant
Ensure that pump can prime lubricant
Level monitoring
glows
Barrel / container empty
Change barrel / fill up container
Level monitoring
glows, but barrel is
filled up
Level sensor defective
Replace level sensor
Line to level sensor defective
Insert new line
No pressure is build
up in pump
Sealing bush of drive piston defective.
Renew sealing bush (see 13.3)
Suction valve of pump defective or
polluted.
Renew or clean suction valve or pump (see
13.1)
Air inclusions in lubricant
Ensure that pump can prime lubricant
Motor does not
operate
Braids connected wrong
Correct connection of braids
Motor defective
Change motor (see 13.2)
Notice!