Page
19 ©
BEKA 2017 All rights reserved!
...a product of
12.
Maintenance
Disconnect the device from power supply before
maintenance or repair.
Maintenance and repair
may only be carried out at
complete
standstill
and under
pressureless condition
.
Check the surface temperature of the device, as there is the
risk of burns
by radiant heat. Wear heat-resistant gloves
and safety goggles! Soiled or contaminated surfaces have to be cleaned before maintenance, wear protective
equipment to this purpose, if necessary! Protect the device against recommissioning during maintenance/repairs!
Further information and technical details regarding the components can be found in the enclosed operating manuals
of the components.
12.1 General
maintenance
Retighten all fittings 6 weeks after start up!
Check all components for leakages and damage at least every four weeks!
If leakages are not repaired, lubricant
might
come out there under high pressure
. Remove possible puddles of
lubricant immediately.
12.2 Lubricant
change
Observe utmost
cleanness
when refilling lubricant!
Check the level regularly and refill clean lubricant as necessary, see chapter start up.
Lubricant change has to be done according to the specifications of the lubricant manufacturer. Environmental influences like
increased temperature or pollution may make it necessary to shorten these intervals!
Please take care to only use lubricants that are suitable for the device as well as the lubricated machine and that comply with the
requirements of the particular operating conditions.
In case of
different lubricant manufacturers
, ensure that the lubricant
quality
corresponds to the quality of the previously used
one! As precautionary measure, drain the lubricant reservoir professionally and clean it!
12.3 Filling of the container
1. Step:
Depressurize the pump and protect it against unintentional operation.
2. Step:
Remove the screw plug at the filling connection G1 (1) (hexagonal socket
SW 17) and connect the filling pump at the filling connection of the device.
3. Step:
Slowly fill up the device with lubricant, until lubricant comes out of the overfill
protection (2). Dispose surplus lubricant environmental friendly.
4. Step:
Remove the filling pump and close the filling connection (1).
Caution!
2