7.  ACCESSORIES

7.1  Scale and tag marking

BA644DF-F indicators are fitted with a blank
escutcheon around the liquid crystal display.  If
specified when the instrument is ordered, this can
be supplied printed with units of measurement and
tag information, plus a scale for the horizontal
bargraph.  Alternatively, information may be added
on-site via an embossed strip, dry transfer or a
permanent marker.

If separate units of measurement or identification
are required for each process variable this can be
provided on the tag plate see 7.2

To gain access to the display escutcheon remove
the terminal cover by unscrewing the two 'A'
screws which will reveal two concealed 'D' screws.
Unscrew all four 'D' screws and carefully lift off the
front of the instrument.   The location of these
screws is shown in Fig 2.

After adding the required legends, or fitting a new
pre-printed self-adhesive escutcheon, ensure that
the gasket is correctly positioned before
reassembling the instrument enclosure.

7.2  Tag plate

The BA644DF-F can be supplied with a blank or
custom laser marked stainless steel plate secured
by two screws to the front of the instrument
enclosure. This plate can accommodate:

        1 row of 9 alphanumeric characters 10mm high

   or  1 row of 11 alphanumeric characters 7mm high

   or  2 rows of 18 alphanumeric characters 5mm
        high.

   or  8 cells each containing units of measurement or
         identification for one of the 8 inputs.

Fig 7  Typical 8 cell tag plate

7.3  Pipe mounting kits

Two pipe mounting kits are available for securing
the BA644DF-F to a horizontal or vertical pipe.

BA392D Stainless steel bracket secured by two

worm drive hose clips for 60 to 80mm
outside diameter pipes.

BA393

Heavy-duty stainless steel bracket
secured by a single 'V' bolt.  Will clamp
to any pipe with an outside diameter
between 40 and 80mm.

Summary of Contents for FOUNDATION BA644DF-F

Page 1: ...Issue 4 4th March 2014 BA644DF F FOUNDATION fieldbus Field mounting 8 variable Fieldbus Indicator Issue 4...

Page 2: ...display parameters 5 3 6 Enable selected input 5 3 7 Enter Device Address 5 3 8 Enter Variable Identity 5 3 9 Decimal point position 5 3 10 Configuration of bargraph 5 3 11 Scale numeric display 5 3...

Page 3: ...protocol is shown on a label inside the terminal cover The F order code suffix also indicates the protocol but is not shown on the instrument identification label There is an alternative version of t...

Page 4: ...arth terminal should be connected to the potential equalising network The BA644DF F enclosure is supplied with a bonding plate to ensure electrical continuity between the three conduit cable entries 4...

Page 5: ...5 Fig 3 Dimensions and terminal connections...

Page 6: ...nditioned as a fieldbus listener see section 5 3 13 to change it to a fieldbus node 5 2 1 Reset the indicator to node factory defaults rESEt The BA644DF F may be reset to the factory defaults that are...

Page 7: ...the P button causes the BA644DF F indicator to search the fieldbus segment to which it is connected for all publishers Fig 5 shows how the indicator displays the hexadecimal Device Address and Variabl...

Page 8: ...vice Address and Variable Identity Parameters can not be changed from within this function See section 5 3 4 Edit Enter addresses and display parameters Contains six sub functions that enable known fi...

Page 9: ...9...

Page 10: ...isplayed pressing E will allocate the selected process variable to the selected input and return the display to the Device Address and Variable Identity from which another process variable may be sele...

Page 11: ...function pressing P again will reveal the existing bargraph justification The or button will scroll through the four options when the required justification is displayed pressing E will enter the sele...

Page 12: ...ration menu using the or button To enter the function press P which will show that the instrument is configured as a fieldbus listener to change to a fieldbus node press the or button which will toggl...

Page 13: ...nfiguration All display segments activated Display is initialising This is normal operation after a few seconds the model number followed by the firmware version will be displayed prior to entering th...

Page 14: ...After adding the required legends or fitting a new pre printed self adhesive escutcheon ensure that the gasket is correctly positioned before reassembling the instrument enclosure 7 2 Tag plate The BA...

Reviews: