6.3.1 Access
Access to the listener configuration menu is
obtained by operating the
P
and
E
buttons
simultaneously. If the BA444NDF-P listener
configuration menu is not protected by an access
code the first parameter 'SCAn’ will be displayed.
If the BA444NDF-P is protected by an access
code, ‘CodE’ will be displayed first. Pressing
P
will
allow the four digit security code to be entered digit
by digit using the
▼
or
▲
button to adjust the
flashing digit and
P
to move control to the next
digit. When the correct code has been entered,
pressing
E
will cause the first parameter ‘SCAn’ to
be displayed. If an incorrect code is entered, or
no button is pressed for ten seconds, the indicator
will automatically return to the display mode.
Section 6.3.2 contains a summary of each
configuration function including a cross reference
to a more detailed description.
6.3.2 Summary of listener configuration
functions
Instrument Summary
display of function
‘SCAn’
Scan fieldbus segment
Identifies
all data sources on the
fieldbus segment to which the listener is
connected and enables selected data to
be allocated to one of the eight listener
inputs in-1 to in-8.
See section 6.4.1
‘LiSt’
List configured input parameters
For each of the eight BA444NDF-P
listener inputs, in-1 to in-8 shows if the
input is enabled, Source Address,
Destination Address and the Index
which have been allocated.
Parameters can not be changed from
within this function.
See section 6.4.2
‘Edit’
Enter addresses and display
parameters
Sub-menu which allows known fieldbus
device addresses to be entered and all
display parameters adjusted for each of
the eight fieldbus listener inputs.
See section 6.4.3
‘Enb’
Enable selected input
Enables each of the eight
listener inputs in-1 to in-8 to
be enabled or disabled
without affecting any
parameters.
See section 6.4.4
‘SrC’
Enter Source Address
Allows hexadecimal fieldbus
device source address for
each of the eight listener
inputs in-1 to in-8 to be
entered.
See section 6.4.5
‘dSt’
Enter Destination Address
Allows hexadecimal fieldbus
device destination address
for each listener input in-1 to
in-8 to be entered.
See section 6.4.6
‘ind’
Enter Index
Allows hexadecimal index
for specified fieldbus source
address to be entered for
each listener input in-1 to
in-8.
See section 6.4.7
‘dP’
Decimal point position
Defines position of displayed
decimal point for each
listener input in-1 to in-8.
See section 6.4.8
‘bAr’
Configuration of bargraph
Defines the bargraphs
justification and the digital
display at which the
bargraph is zero and full
scale for each listener input
in-1 to in-8.
See section 6.4.9
‘SCALE’ Scale numeric display
Applies zero offset and
scale factor to the numeric
display for each listener
input in-1 to in-8.
See section 6.4.10
‘CodE’
Access code for listener
configuration menu
Enters a four digit security access
code for configuration menu. Default
code 0000 disables this function.
See section 6.4.11
‘
tYPE’
Change from listener to node
Enables the instrument to be
conditioned as a fieldbus listener or a
fieldbus node.
See section 6.4.12
‘rESEt’
Reset to listener factory defaults
Returns the BA444NDF-P listener to
factory defaults.
See section 6.4.13