V1.0K3                                PULSE OXIMETER INSTRUCTION MANUAL

 

 

30

Not-original package lead to oximeter during transportation 

Not-professional person operation leads to oximeter failure. Not our company 

professionals or authorized personnel disassemble oximeter and lead to oximeter 
failure. 

Not carefully read manual and so wrong operation lead to oximeter damage and failure. 

7.5.5 User’s Special Request for Guarantee Time 

Our guarantee constitution for oximeter complies with electronic product after-sale service 
standard regulated by national laws. The guarantee time of mainboard regulated by our 
company is one year and all the accessories are three months. If users request the 
guarantee time beyond our regulated guarantee time, we should take it into consideration. 
Because electronic product has such a character of changing quickly, for such user asking 
more than three years guarantee time, our company will not buy oximeter parts during 
maintenance. Our company will upgrade oximeter or change new maintenance methods, 
for this, we charge the lowest price for new oximeter with user permission. 

7.5.6 Repackage 

Take all the accessories and put them into plastic cover 

Try to use original package and packing material. user will be responsible for such 

damage caused by bad package during transportation. 

Please offer guarantee list and copy of invoice to standby with the period of guarantee. 

Please describe failure phenomenon in detail and altogether offer oximeter.   

7.6 Storage and Transportation 

Storage: Storage Temperature -20

55

, Relative Humidity 

93%, no condensation 

Transportation: Transport by airline, train or vessel after packing according to request. 

Package: We pack the product with the hard bag. We put the foam between the inner box 
and the cartoon to alleviate the shake. 

APPENDIX A Specifications 

Notes: 

z

 

Specifications may be changed without prior notice. 

z

 

The circuit diagrams, the list of components, the illustrations of diagrams, 
and the detailed rules of calibration are provided exclusively to professional 

Summary of Contents for MD300K3

Page 1: ...sly authorized by our company All information contained in this publication is believed to be correct We shall not be liable for errors contained herein nor for incidental or consequential damages in...

Page 2: ...2 2 Rear Panel 9 2 3 Power Supply 9 3 Install SpO2 Probe 11 4 Setting ID Date and Time 12 4 1 Date Time Settings 12 4 2 ID number Setting 13 5 Take a Measurement 14 6 Other Settings 17 6 1 Alarm Sett...

Page 3: ...hazard or unsafe practice that if not avoided could result in minor personal injury or product property damage Note Provides application tips or other useful information to ensure that you get the mos...

Page 4: ...ed and to protect user under safety situation z To avoid an electrical hazard never immerse the unit in any liquid or attempt to clean it with liquid cleaning agents Always disconnect the device from...

Page 5: ...z It is not recommended to take measurements during battery charging z Our company will only provide the schematic components list legend and correction details for the qualified technical personnel a...

Page 6: ...plied part IPX1 Protected against dripping water ID indication Battery power indication Audible alarm on Audible alarm inhibition Pulse Beep on Pulse Beep off Keyboard is unlocked Keyboard is locked U...

Page 7: ...ttery power alarm Data transfer to PC by USB cable or Bluetooth Powered by four AA alkaline Ni MH batteries power adapter Battery charge function with adapter optional Suitable for adult and pediatric...

Page 8: ...7 Fig 2 1 Description of Fig 2 1 1 Fixing clip for the SpO2 probe 2 Displaying screen 3 Print Button Press this button to turn on off the function of printing 4 OK Button Press this button to enter me...

Page 9: ...dapter socket For connecting the power adapter 11 Paper Feed button When the printing function is turned on you can press the button to start printing 12 SpO2 socket For connecting the SpO2 probe with...

Page 10: ...e printing paper 4 The cover of battery compartment Fig 2 2 2 3 Power Supply The device can be powered by 4 AA alkaline batteries Ni MH batteries or power adapter 2 3 1 Powered by batteries Batteries...

Page 11: ...l become empty and at the same time its frame will become red which means little of battery capacity remains You should replace the batteries with new ones in time The unit will shut down when the bat...

Page 12: ...it please make sure the adapter is firstly connected with the oximeter and secondly with the wall outlet While disconnected the connection please make sure the adapter is firstly disconnected from the...

Page 13: ...ransmission For more information on data transmission and data management refer to the corresponding software instruction manual 4 Setting ID Date and Time Always set the date and time before using th...

Page 14: ...or Down button to adjust the value At last press the OK button to confirm your settings 4 2 ID number Setting Enter the User ID Setting item from the main menu screen refer to Fig 4 3 Press the OK bu...

Page 15: ...z Do not use the SpO2 probe with exposed optical components z Excessive patient movement may cause inaccurate measurements z Tissue damage can be caused by incorrect application of the probe for exam...

Page 16: ...any of the following situations z The probe is too tight z There is excessive illumination from light sources such as a surgical lamp a bilirubin lamp or sunlight z A blood pressure cuff is inflated o...

Page 17: ...ng normal measurement The color of the SpO2 value will become red when the SpO2 value exceeds the alarm limits It shows two dashes throughout probe off and finger out conditions 100 SpO2 high alarm li...

Page 18: ...hen press the OK button again to confirm the setting of SpO2 high limit The range of SpO2 high limit is 71 100 Fig 6 1 Set the low limit for SpO2 alarm as the above steps of SpO2 high limit settings T...

Page 19: ...w Lamp Frequency 1 5Hz 0 5Hz Audiblesound Di Di Di Di Di Di Di Di Di Alarm cycle 3 s 5 s 20 s Alarm info SpO2 too high low PR too high low Probe off Finger out AUDIBLE ALARM INHIBITION Short press the...

Page 20: ...s that have saved in the unit by pressing the Up or Down button Press the OK button a dialog box will pop up refer to Fig 6 4 After selecting a ID number press the Up or Down button to select Delete o...

Page 21: ...2 trends saved under this ID Fig 6 5 Fig 6 6 6 2 3 PR Trend The specific operations are as the same as SpO2 Trend please refer to 6 2 2 SpO2 Trend 6 2 4 Delete Data Pick and enter the Delete Data sub...

Page 22: ...rting a SD card Insert a SD card into the micro SD socket located in the right side of the unit then the SD mark will be displayed in the middle status bar of the screen Do not insert the SD card hard...

Page 23: ...ght time Brightness level 1 7 Bright time ON 15 30 45 60 75 90 105 120 seconds Note The brightness cannot be set in the charging process 6 3 2 Bluetooth Enter Bluetooth setting screen from the System...

Page 24: ...System Setting screen and set the auto power off time and the auto power off on off Auto power off time Set the time that no operation lasts before the device automatically powers off Time 1 2 3 4 5...

Page 25: ...1 Fig 6 11 Fig 6 12 4 When the paper comes out from the outlet as shown in Fig 6 12 it means that the printing paper is installed well The unit will perform printing 6 3 8 Restore Enter Restore screen...

Page 26: ...use lowest possible concentration z Do not immerse any part of the equipment into liquid z Do not pour liquid onto the equipment or accessories z Do not allow liquid to enter the case z Never use abra...

Page 27: ...e bleach diluted z Hydrogen peroxide 3 z Ethanol 70 z Isopropanol 70 To clean your equipment follow these rules 1 Shut down the pulse oximeter and take the batteries out of the battery compartment 2 C...

Page 28: ...nd Verification The performance should be checked every one year and after maintenance and repair Required Test Equipment SpO2 signal Simulator Note The simulator cannot be used to assess the accuracy...

Page 29: ...th extension cable please check if the extension cable is connected with the probe correctly 7 5 Warranty and Repair 7 5 1 Maintenance Method a Maintenance responding time 9 00am 17 30pm Monday to Fri...

Page 30: ...lity limitation During the period of maintenance contract validity if user changes the parts manufactured by other manufacturers without our company permission our company is entitled to stop contract...

Page 31: ...oximeter parts during maintenance Our company will upgrade oximeter or change new maintenance methods for this we charge the lowest price for new oximeter with user permission 7 5 6 Repackage Take al...

Page 32: ...ications Wavelength Radiant Power RED 660 2nm 1 8mW IR 940 10nm 2 0mW Pulse Rate Display range 0 254 bpm Measurement range 30 235 bpm Resolution 1 bpm Accuracy 2 bpm or 2 The larger Alarm Alarm SpO2 a...

Page 33: ...Environment Requirements Operation temperature 5 40 Operation humidity 80 no condensation Storage temperature 20 55 Storage humidity 93 no condensation Power supply Four AA alkaline or Ni MH batterie...

Page 34: ...ne 2GB SD card z Optional accessories 1 One Power adapter 2 Four AA Ni MH batteries 3 One disposable sponge wrap sensor for adult Model M 50J Manufacturer address Beijing Choice Electronic Technology...

Page 35: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Reviews: