References marked on instrument or in
instruction manual:
Warning of a potential danger, comply with in-
struction manual.
Reference. Please use utmost attention.
Caution! Dangerous voltage. Danger of electri-
cal shock.
Warning of potential danger caused by accu-
mulators and batteries.
Continuous double or reinforced insulation
complies with category II, IEC 60536.
Symbol for the marking of electrical and elec-
tronic equipment (WEEE Directive
2002/96/EC).
Conformity symbol, the instrument complies
with the valid directives. It complies with the
EMC Directive (89/336/EEC). It also complies
with the Low Voltage Directive (73/23/EEC).
The instruction manual contains information
and references, necessary for safe operation
and maintenance of the instrument. Prior to
using the instrument (commissioning / as-
sembly) the user is kindly requested to thor-
oughly read the instruction manual and com-
ply with it in all sections.
Failure to read the instruction manual or to
comply with the warnings and references
contained herein can result in serious bodily
injury or instrument damage.
1.0 Introduction
You have purchased a high quality measurement in-
strument of Ch. BEHA GmbH which will allow you
to carry out reproducible measurements over a long
time period. The company Ch. BEHA GmbH is a
member of the world-wide operating BEHA Group
with its head office in Glottertal/Schwarzwald which
also houses the technological centre. The BEHA
Group is a leading manufacturer of Test and Mea-
surement Instruments.
1.1 Model and Type Designation
The type shield sticker is located on the bottom of
the instrument. It contains the instrument serial
number and product designation. When questions
arise regarding the instrument, please always quote
product number and serial number.
1.1 Product Description
The UNITEST 0100-ELECTROcheck is a handy and
compact test instrument for easy and fast testing of
installations in compliance with DIN VDE 0100,
ideal for the specialist for defined tasks.
The UNITEST 0100-ELECTROcheck is charac-
terised by the following:
•
Display for good/fail indication, no display of
measurement values
•
Integrated socket test for fast determination of
wrongly connected socket or missing protective
conductor
•
Low impedance or continuity test
•
Insulation test with 500 V DC test voltage
•
Loop resistance test
•
Internal resistance test
•
Verification of contact voltage in systems
equipped with RCD
•
Tests of RCDs with nominal residual currents of
30...500 mA
•
Phase sequence in networks up to 415 V
•
Energy management, auto power off
•
Built in compliance with DIN VDE 0413, EN
61557, IEC 61557, DIN VDE 0411, EN 61010,
IEC 61010
4
Introduction
PTDB90510001.qxd 02.03.2006 12:23 Uhr Seite 48