GT-650/GT-900 User's Manual
60
1 ...... “
” menu key, to switch between two selections of menu keys.
2 ...... “TODO” menu key, to check the list of all appliance codes* in the database
which are not tested yet. TODO will be displayed at the upper line as a
header and number of not tested appliances* will be displayed in window 6.
After pressing the “TODO” menu key desired appliance codes* to be
tested can be selected. Use the “EXIT” function key to exit TODO
mode.
3 ...... “NEW” menu key, to create/enter new appliance code*.
Note! Each appliance code must be unique under the same client (two
equal appliance codes are not allowed, the GT-650/GT-900 tester
will block double entering the same appliance code).
4 ...... “SEL” menu key, to display list of all appliance codes* (no appliance root is
entered) or just a list of appliance codes* containing entered root
(appliance root is entered). Wished appliance root can be entered after
changing the selection of menu keys by pressing the “
” menu key.
5 ...... Window reserved for displaying the first three of all appliance codes*
(no appliance root is entered) or just the first three of appliance codes*
containing entered root (appliance root is entered). These Appliance
Codes* will be selectable after pressing the “SEL” menu key.
6 ...... Window reserved for displaying the number of all appliance codes* in
database or for displaying the number of only not tested appliances*, if
“TODO” mode is used.
Notes!
In both cases (TODO mode used or TODO mode not used) the number in
window 6 depends also on entered appliance root. If no appliance root is
entered, then number of all appliance codes* will be displayed.
If there are no appliance codes* in database yet (= empty), then keys
“TODO” and “SEL” will not be offered.
Explanation of the star sign (*) used in this manual:
Parameters/expressions marked with the * sign refer to selected client
code only (client code is selected in MENU / CLIENT menu) or to all client
codes in database (client code is disabled – FILTER DISABLED is displayed in
MENU / CLIENT menu), see the section “CLIENT menu” on page 70.
Test procedure for AUTO-TEST standard way in STANDARD mode:
Standard way means that an appliance code* with belonging attributes is
selected/entered before starting the AUTO-TEST as offered on the display.
STANDARD mode means that test steps are done one after another with manual
start (START key) of each step.
STEP 1
As shown in the figure 46 above, the first step in AUTO function is to select an
appliance code where the AUTO-TEST will be carried out.
Select one of existing appliance codes* from database:
Press the “SEL” menu key in idle display, the list of first four entered appliance
codes* will be displayed. Select wished appliance code by using the “
” and “
”
menu keys and confirm it by pressing the “
“ (Enter) menu key.