EN
32
Descaling with the BEEM
Premium
Descaler Concentrate
1. Fill the kettle (
3
) up to the
MAX
marking with a concentrate/water solution of no more than
1:20 (one part concentrate to 20 parts water).
2. Press the temperature button 100°C (
13
) and the
On
/ Off button (
9
) to switch on the
device. The control lamps in both buttons light up. The solution starts boiling.
3. As soon as the solution has boiled, the device switches off. Allow the solution to take effect for
a little while.
4. Pour away the solution.
5. To rinse the kettle, boil up clear water twice and pour this water away. The device is now
descaled and ready to be used again.
Storage
Disconnect the device from the mains power when it is not going to be used for a prolonged
period. Clean the device again if necessary (see the “Cleaning and Care” chapter) and let it dry
completely.
Store the device and all accessories in a dry, clean, frost-free place that is protected from direct
sunlight and cannot be accessed by children or animals.
Troubleshooting
If the device does not work properly, check whether you are able to rectify the problem your-
self. If the problem cannot be solved with the steps that are listed, contact our customer service
department.
Do not attempt to repair an electrical device yourself!
Problem
Possible
cause
Fix
The device cannot
be switched on.
The mains plug is not inserted
correctly in the plug socket.
Insert the mains plug.
The plug socket is defective.
Try another plug socket.
There is no mains voltage.
Check the fuse of the mains
connection.
The
On / Off button (
9
) has
not been pressed.
Press the
On / Off button to
switch on the device.
The device cannot
be switched on. You
will hear three short
beeps.
The water in the kettle
(
3
) is
hotter than the selected temper-
ature level.
Allow the water in the kettle to
cool down before the device is
switched on again.