Beech Ovens
Page 56
2/09/2019 (C)
E-Series Manual (R4)
Confidential and Proprietary
General Technical Details
The data plate mounted on the inside of the lower access door contains the specific
information for your oven. The following information is general technical details for all
ovens and related Gas types, based on an 80Mj Gas Burner.
Natural
ULPG
Gas Pressure at
Burner Injector
1kPa (High)
2.65kPa
(High)
Gas Pressure at
Isolating Valve
1.0kPa (Min)
5.0kPa (Max)
2.65kPa (Min)
5.0kPa (Max)
Gas
Consumption per
Hour (approx.)
2.0 m³/ Hr
0.6 m³/ Hr
Timber
consumed
Hardwood, no
Gas Lunch and
Dinner
0.1 m³/ day
Secondary air for
Gas Burner
(Equivalent to a 40cm x
40cm vent under the oven
floor)
5.66 litres/sec
Air Conditioning
Heat Load
<2kW Heat Load
The following table shows the correct jet orifice size for the standard Beech Ovens
gas burners.
Gas output (Mj)
Natural Gas
ULPG
30Mj
2.45mm
1.60mm
40Mj
2.95mm
1.85mm
50Mj
3.20mm
2.10mm
60Mj
3.60mm
2.30mm
70Mj
3.90mm
2.50mm
80Mj
4.10mm
2.60mm