Beech Ovens
Page 58
2/09/2019 (C)
E-Series Manual (R4)
Confidential and Proprietary
CE Specifications
The following table outlines the technical details for ovens installed within the CE
region.
Natural Gas
Country
Category
Nominal
Pressure
Heat Input
Nominal
Rate
Injector
Diameter
DE
I2ELL
20mBar
G20: 22kW
G25: 19kW
2.3m ³/Hr
3.5mm (28 gauge)
AT, DK, EE, FI,
IT, LT, NO, PT,
RO, SE, SK, TR,
BG, CH, CY, CZ,
ES, GB, GR, IE,
SI
I2H
20mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
BE
I2E(R)
20/25mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
FR
I2Er
20/25mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
NL
I2L
25mBar
G25: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
HU
I2H
25mBar
G20: 22kW
2.3m ³/Hr
3.5mm (28 gauge)
ULPG
CH, DE, NL,
FR, ES
I3P
50mBar
G31: 18.5kW
1.44kg /Hr
2.2mm (44 gauge)
FR, LU, CH, CZ,
GB, GR, IE, SI,
BR, ES, BE, PT,
SK, PL
I3P
37mBar
G31: 18.5kW
1.44kg /Hr
2.2mm (44 gauge)
Note:
CH, FR and ES allow both 37 and 50mBar
Timber Consumption:
Hardwood
0.1m
³
/ day
Airflow required:
450 litres / sec. Suction controlled by system damper. (Direct connect)
Duct Size: Natural Draft
300mm square (900cm²) or equivalent area round.
Duct Size: Fan assisted
300mm square (900cm²) or equivalent area round.
Duct Material:
1.2mm galvanised or 0.9mm stainless steel
(As per local regulation)
Secondary Air for gas
burner:
6 litres / sec (approximately)
Air conditioning Heat
Load:
<2 kW heat load
Electrical Data:
220-240 Volts 50 Hz ac 10 Amp supply with earth