Returns  Procedure  

  
If   your   equipment   requires   servicing,   please   contact   your   local   Bedfont   Customer   Service  
Department,  distributor  or  supplier  before  returning  any  goods.    
  

1.

 

When  you  have  supplied  the  Customer  Repairs  Department  with  the  monitor  serial  number  
and   description   of   the   fault,   you   will   be   issued   with   a   returns/   ticket   number.   Please   state  
the   returns/ticket   number   on   the   outside   of   the   box   when   returning   the   monitor,   and  
ensure  that  your  full  details,  telephone,  fax  numbers  and  return  address  are  clearly  stated.    

2.

 

The   product   must   also   be   decontaminated   before   it   is   returned   according   to   your   local  
regulations.  Bedfont  can  provide  you  with  a  decontamination  certificate  to  complete,  which  
also  needs  to  be  attached  to  the  outside  of  the  box.  Failure  to  do  so  will  result  in  the  product  
being  subject  to  Bedfont  decontamination  procedure  and  will  delay  your  service/repair.  

3.

 

Bedfont  advise  that  you  use  a  courier  service  when  returning  monitors.  This  enables  you  to  
insure  goods  for  loss  or  damage  in  transit.  When  your  goods  are  received,  you  will  be  sent  
an  email  stating  so.    

4.

 

If  the  device  has  been  returned  for  repair  it  will  then  be  examined  and  you  will  be  sent  an  
‘Engineer’s  Report’  and  a  quotation  for  the  repair,  which  will  include  an  authorisation  form.  
Complete  the  authorisation  form,  and  ensure  that  you  include  the  ‘Official  Purchase  Order  
Number’.   Please   contact   the   Customer   Repairs   Department   if   you   are   unable   to   supply   an  
‘Official  Purchase  Order  Number’.  

5.

 

If   your   monitor   is   still   in   warranty   and   the   fault   is   covered   by   warranty,   see   ‘Warranty’  
section  of  this  manual,  Bedfont  will  repair  it  and  return  it  to  you  with  an  ‘Engineer’s  Report’,  
free  of  charge.    

6.

 

If  you  choose  not  to  proceed  with  the  repair,  a  handling  fee  will  be  charged.  Ensure  that  you  
return  the  completed  authorisation  form  with  an  ‘Official  Purchase  Order  Number’.    

7.

 

The   equipment   will   be   returned   to   you   as   soon   as   Bedfont   has   received   all   relevant  
paperwork.  A  carriage  fee  will  be  charged  if  the  monitor  is  no  longer  in  warranty.  
  

Spares  

D-­‐PIECE-­‐2  

Box  of  12  D-­‐Pieces  (non-­‐sterile)  

STERIBREATH  

Box  of  250  SteriBreath  Mouthpieces  (non-­‐sterile)  

WIPE-­‐V  

Pack  of  50  Cleaning  Wipes    

FXS397  

USB  Cable  

  
Warranty  

  
Bedfont   Scientific   Limited   warrants   the   piCO™,   piCO

baby

  

and   Micro

+

™   Smokerlyzer®   products  

(excluding   batteries)   to   be   free   of   defects   in   materials   and   workmanship   for   a   period   of   five   years  
from   the   date   of   shipment.   Bedfont’s   sole   obligation   under   this   warranty   is   limited   to   repairing   or  
replacing,  at  its  choice,  any  item  covered  under  this  warranty  when  such  an  item  is  returned,  intact  
and   prepaid,   to   Bedfont   Scientific   Limited   or   the   local   representative.   These   warranties   are  
automatically   invalidated   if   the   products   are   repaired;   altered,   void   labels   removed   or   otherwise  
tampered  with  by  unauthorised  personnel,  or  have  been  subject  to  misuse,  neglect  or  accident.  
Never   dispose   of   any   electronic   instrument   or   batteries   in   domestic   waste.   At   the   end   of   the  
product’s  life,  contact  Bedfont  or  its  distributor  for  disposal  instructions.  
  
  
  
  
  

Summary of Contents for Smokerlyzer Range

Page 1: ...Smokerlyzer Range For use with piCO piCObaby and Micro Scientific contributions to health User manual ...

Page 2: ... and time Micro only 3 Traffic Light Pre set Cut Off Levels 4 Technical Specification 4 Safety Information and Device Symbols 4 Environment 5 Instrument Layout 5 Display and Device Symbols 6 Warnings and Maintenance 8 Cleaning 8 Routine Maintenance 9 Troubleshooting 9 COdata Software connecting to the PC 10 Returns Procedure 11 Spares 11 Warranty 11 ...

Page 3: ...has been inhaled and the COHb and fCOHb readings relate to the percentage of vital oxygen that has been replaced in the bloodstream The piCO Smokerlyzer displays both CO ppm and COHb the piCObaby Smokerlyzer displays both CO ppm FCOHb and COHb and the Micro Smokerlyzer displays CO ppm COHb and FCOHb However all devices only directly measure CO ppm the COHb and fCOHb is a calculation based on clini...

Page 4: ...ly useful in the event of a patient reporting a non smoker status but providing a breath reading of that of a smoker suggesting they have inhaled environmental CO This is carried out by pressing on the screen the Micro will then carry out real time monitoring of the environmental air To stop the test press Bedfont do not recommend that the environmental test alone is used as a measure of passive s...

Page 5: ...es on new alkaline batteries approx 3 min per use Approx 1 x CR2032 Battery Life 175 000 hours T90 Response Time 30 seconds Operating Temperature Range 0 40 C storage 0 50 C Operating Transport Storage Pressure 800 1200mbar Operating Humidity 10 90 non condensing storage 0 95 Sensor Operating Life 5 years 5 year warranty Sensor Sensitivity 1ppm Sensor Drift 5 per annum Dimensions Approx 34 x 75 x ...

Page 6: ... by cellular phones and by electromagnetic interference exceeding the levels specified in EN50082 1 This equipment should be moved if necessary to avoid interference Instrument Layout 1 Display 2 Power button 3 Breath sampling D Piece 4 D Piece aperture 5 Exhaust port for breath sample 6 USB connector for use with COdata Software 7 Single use SteriBreath mouthpiece 8 Battery compartment 9 Battery ...

Page 7: ...Micro Battery condition Full Battery condition Low Battery condition Empty Breath Test Environmental Test N A N A Settings Patient Profiles N A N A View patient results N A N A Inhale Hold Breath Countdown Timer Exhale ppm Reading COHb Reading Show fCOHb N A ...

Page 8: ... fCOHb Reading N A Ambient CO reading N A N A Home Change D Piece Change Traffic Light Cut off Levels Save N A N A Change Breath Hold Time N A N A History N A N A Mute Next Step Countdown to Sensor Change Change Sensor Calibrate Device ...

Page 9: ...ning to appropriately qualified persons 5 Holding the reset button down for 30 seconds will perform complete device reset this will clear any saved data and revert all settings to the factory defaults After performing a reset the device will need to have the date time set and be calibrated before it can be used Cleaning 1 The Smokerlyzer products are moulded with SteriTouch technology for optimum ...

Page 10: ...mbols moulded into the plastic High readings recorded for reported non smoker If a breath test on a non smoker gives an indication of CO being present it may indicate the following 1 A high ambient level of CO possibly due to a faulty combustion appliance or exhaust fumes 2 The effects of passive smoking 3 The device is contaminated by alcohol or another organic substance 4 The patient may have a ...

Page 11: ... be shown onscreen Follow the onscreen instructions to finish the calibration process 6 Gas flow should be set to 1 0 litres per minute 7 A successful calibration will be indicated by the press to return to the home screen 8 A failed calibration will be indicated by press to attempt calibration again If the problem persists see Troubleshooting or call your local supplier of Bedfont products 9 Retu...

Page 12: ...Department if you are unable to supply an Official Purchase Order Number 5 If your monitor is still in warranty and the fault is covered by warranty see Warranty section of this manual Bedfont will repair it and return it to you with an Engineer s Report free of charge 6 If you choose not to proceed with the repair a handling fee will be charged Ensure that you return the completed authorisation f...

Page 13: ... heure Seulement Micro 14 Classification du fumeur et code couleur prédéfini 15 Spécifications techniques 15 Informations de sécurité des icônes 15 Environnement 16 Schéma d appareil 17 Affichage et icônes d appareil 17 Avertissements et maintenance 20 Nettoyage 20 Entretien courant 21 Dépannage 21 Logiciel COdata branchement au PC 22 Procédure de retour 22 Pièces consommables 23 Garantie 23 ...

Page 14: ...té de gaz dans les poumons les voies respiratoires correspondant à la quantité de CO nocif qui a été inhalée et la COHb et fCOHb à la quantité de gaz présente dans le sang L analyseur piCO Smokerlyzer affiche la concentration en CO ainsi que COHb Le piCObaby Smokerlyzer et le Micro Smokerlyzer affichent en plus fCOHb Cependant tous ces appareils ne mesurent que directement ppm CO la COHb et fCOHb ...

Page 15: ...on enfoncé pendant 3 secondes L analyseur s éteindra automatiquement après 2 minutes d inactivité Effectuer un test ambiant Seulement Micro Avec le Micro Smokerlyzer l air ambiant peut être analysé pour vérifier la concentration de CO dans l environnement Ceci est particulièrement utile dans le cas où un patient qui est signalé comme étant non fumeur et obtient un résultat correspondant à celui d ...

Page 16: ...modifiées Spécifications techniques piCO piCObaby Micro Plage de concentration CO 0 150ppm 0 150ppm 0 500ppm Affichage Ecran tactile couleur Principe de détection Capteur électrochimique Répétabilité 3 sur lectures consécutives Interférence avec H2 6 Alimentation électrique 3 x AA LR6 ou équivalent 1 x CR2032 pile au lithium Autonomie avec 3 piles AA 1 000 utilisations avec des piles alcalines neu...

Page 17: ...ce des mélanges inflammables Référer aux instructions pour l utilisation Courant continu Marquage CE Pièce appliquée de type BF Eliminer selon DEEE Numéro de série Fabricant et date de fabrication Logo de Bedfont Environnement Le piCO piCObaby et le Micro Smokerlyzer sont conformes à la norme EN60601 1 2 sur la compatibilité électromagnétique mais peuvent être affectés par les téléphones portables...

Page 18: ... pour utilisation avec le logiciel COdata 7 Embout buccal SteriBreath à usage unique 8 Compartiment des piles 9 Clip de compartiment des piles 10 Bouton de réinitialisation 11 Interrupteur de programmation Affichage et icônes d appareil Description piCO piCObaby Micro Etat des pile Pleine Etat des piles Faible Etat des piles Vide Test respiratoire Test ambiant N A N A Paramètres ...

Page 19: ...Profils des patients N A N A Afficher les résultats mémorisés N A N A Inspirer Retenir la respiration Compte à rebours Expirer doucement et complètement Lecture en ppm Lecture en COHb Afficher la fCOHb N A ...

Page 20: ... N A Accueil Remplacer le piégeur Dpiece Modifier les seuils de classification du fumeur Enregistrer N A N A Modifier le compte à rebours pour le temps d apnée N A N A Historique N A N A Volume Prochaine étape Date de remplacement du capteur Remplacer le capteur Etalonner l appareil ...

Page 21: ...u dispositif 10 En maintenant le bouton de réinitialisation pendant 30 secondes le dispositif se réinitialisera complétement ceci effacera toutes les données enregistrées et rétablira tous les paramètres aux valeurs par défaut Après une réinitialisation il faut vérifier l heure et la date et étalonner le dispositif avant utilisation Nettoyage 4 Les produits de la gamme Smokerlyzer sont moulés avec...

Page 22: ...es Assurez vous que les piles sont bien placées dans le bon sens dans le compartiment Résultats élevés pour un non fumeur Si un non fumeur obtient des résultats élevés lors du test respiratoire les explications sont les suivants 6 Un niveau élevé de CO ambiant peut être dû à un appareil à combustion défectueux ou à des gaz d échappement 7 Les effets du tabagisme passif 8 L appareil est contaminé p...

Page 23: ...r revenir à l écran d accueil 17 Si l étalonnage a échoué l écran affichera cette icône appuyez sur l icône pour réessayer l étalonnage Si le problème persiste voir Dépannage ou appelez votre revendeur local 18 Appuyez sur l icône pour revenir à l écran d accueil Logiciel COdata branchement au PC Branchez le câble dans le port USB de l ordinateur et le port de connexion USB en haut de l appareil A...

Page 24: ...iel une fois que Bedfont a reçu les documents demandés Si l opération est hors garantie des frais de livraison seront facturés Pièces consommables D PIECE 2 Boîte de 12 piégeurs Dpiece non stérilisable STERIBREATH Boîte de 250 embouts buccaux SteriBreath non stérilisable WIPE V Paquet de 50 lingettes de nettoyage FXS397 Câble USB Garantie Bedfont Scientific Limited garantit les piCO piCObaby Micro...

Page 25: ...e without prior notice Registered in England and Wales Registered No 1289798 Bedfont Scientific Limited 2012 ISO 9001 2008 Cert No FM 31664 ISO 13485 2003 Cert No MD 502905 Contact Bedfont or one of our worldwide Smokerlyzer distributors for a free demonstration www bedfont com Tel 44 0 1622 851122 Email ask bedfont com A full list of our worldwide distributors can be found at http www bedfont com...

Reviews: