Operation
EL6910
44
Version: 1.8.0
Fig. 32: Creating an external connection (Custom FSoE Connection)
Before the connection can be used and linked further, the process image size must be parameterized. This
can be set under the
Process Image
tab. Suitable data types for different numbers of safety data are
provided in the dropdown lists for the input and output parameters.
Fig. 33: Parameterization of the process image size
Once the size is selected, the individual signals within the telegram can be renamed, so that a corresponding
plain text is displayed when these signals are used in the logic. If the signals are not renamed, the default
name is displayed in the editor (Safe Data Byte 0[0], …).