Index 3800 Al range settings
Index
(hex)
Name
Meaning
Data type
Flags
Default
3800:0
Al Range Settings
Maximum subindex
RW
0x0A (10
dec
)
3800:01
Input type Ch1
Input signal range for channel 1
0: -10 V...+10 V
1: 0 mA…20 mA
2: 4 mA…20 mA
3: 0 V…10 V
UINT16
RW
0x0000 (0
dec
)
3800:02
Input type Ch2
Input signal range for channel 2 (values see
channel 1)
UINT16
RW
0x0000 (0
dec
)
3800:03
Input type Ch3
Input signal range for channel 3 (values see
channel 1)
UINT16
RW
0x0000 (0
dec
)
3800:04
Input type Ch4
Input signal range for channel 4 (values see
channel 1)
UINT16
RW
0x0000 (0
dec
)