Foreword

ELX1052, ELX1054 and ELX1058

5

Version: 2.0.0

1

Foreword

1.1

Notes on the documentation

Intended audience

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the documentation and the following notes and explanations are followed when installing
and commissioning these components.
It is the duty of the technical personnel to use the documentation published at the respective time of each
installation and commissioning.

The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development.

We reserve the right to revise and change the documentation at any time and without prior announcement.

No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.

Trademarks

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, EtherCAT G

®

, EtherCAT G10

®

, EtherCAT P

®

, Safety over EtherCAT

®

,

TwinSAFE

®

, XFC

®

, XTS

®

 and XPlanar

®

 are registered trademarks of and licensed by Beckhoff Automation

GmbH. Other designations used in this publication may be trademarks whose use by third parties for their
own purposes could violate the rights of the owners.

Patent Pending

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, EP1456722, EP2137893, DE102015105702 with corresponding
applications or registrations in various other countries.

EtherCAT

®

 is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,

Germany.

Copyright

© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.

Summary of Contents for ELX1052

Page 1: ...Operating manual ELX1052 ELX1054 and ELX1058 Two four and eight channel digital input terminals for NAMUR sensors Ex i 2 0 0 2020 03 09 Version Date...

Page 2: ......

Page 3: ...nditions of use for ELX terminals 17 3 2 Installation notes for ELX terminals 17 3 3 Arrangement of ELX terminals within a bus terminal block 19 3 4 Installation position and minimum distances 22 3 5...

Page 4: ...Table of contents ELX1052 ELX1054 and ELX1058 4 Version 2 0 0...

Page 5: ...e modification of products that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT G EtherCAT...

Page 6: ...nded for trained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instruc...

Page 7: ...erminals updated Technical data updated 1 4 0 Chapter Arrangement of ELX terminals at the bus terminal updated 1 3 0 Chapter Installation notes for ELX terminals updated 1 2 0 Chapter Marking of ELX t...

Page 8: ...nonymous with each revision there is usually a description ESI EtherCAT Slave Information in the form of an XML file which is available for download from the Beckhoff website The revision has been app...

Page 9: ...minal has a unique Beckhoff Traceability Number BTN Ex marking The Ex marking can be found at the top left on the terminal II 3 1 G Ex ec ia Ga IIC T4 Gc II 1 D Ex ia Da IIIC I M1 Ex ia Ma I IECEx BVS...

Page 10: ...Foreword ELX1052 ELX1054 and ELX1058 10 Version 2 0 0 Fig 2 ELX9560 0000 with date code 12150000 BTN 000b000 and Ex marking...

Page 11: ...Foreword ELX1052 ELX1054 and ELX1058 11 Version 2 0 0 Fig 3 ELX9012 with date code 12174444 BTN 0000b0si and Ex marking...

Page 12: ...minal acquires signals from NAMUR field devices according to EN 60947 5 6 The sensors are supplied with a voltage of 8 2 V and return a diagnosable current signal In this way a wire breakage or short...

Page 13: ...osable current signal In this way a wire breakage or short circuit can be detected in addition to the switching state The LEDs indicate signal or any error states channel by channel The sensor supply...

Page 14: ...d records their signals according to IEC 60947 5 6 The sensors are supplied with a voltage of 8 2 V and return a current signal that can be diagnosed In this way in addition to the switching status li...

Page 15: ...typ 10 mA load typ 15 mA load Electrical isolation 1500 V E Bus field potential Bit width in the process image 2 x 2 bit 4 x 2 bit 4 bit input type NC status 8 x 2 bit Weight approx 45 g approx 50 g...

Page 16: ...system with functions for integrating intrinsically safe field devices from hazardous areas The intended field of application is data acquisition and control tasks in discrete and process engineering...

Page 17: ...r removed from the bus terminal system if all supply voltages have been switched off or if a non explosive atmosphere is ensured The connections of the ELX9560 power supply terminal may only be connec...

Page 18: ...housing e g through the ventilation slots in the housing Use only the openings provided in the housing front and appropriate tools to actuate the spring loaded terminal contacts on the front side for...

Page 19: ...ted to the right of an ELX9560 nor to the left of any ELX signal terminal The last terminal of each ELX segment is to be covered by an ELX9012 bus end cover unless two ELX9410 power supply terminals a...

Page 20: ...0 power supply terminal Fig 11 Invalid arrangement missing ELX9560 power supply terminal Fig 12 Invalid arrangement terminal that does not belong to the ELX series within the ELX terminal segment Fig...

Page 21: ...ELX9560 When configuring the ELX terminal segment please note the maximum available output current of the ELX9560 power supply terminal in accordance with the specified technical data If required an...

Page 22: ...lectronics through convection The direction indication down corresponds to the direction of positive acceleration due to gravity Minimum distances Observe the following minimum distances to ensure opt...

Page 23: ...re 1 First attach the fieldbus coupler to the mounting rail 2 The bus terminals are now attached on the right hand side of the fieldbus coupler Join the compo nents with tongue and groove and push the...

Page 24: ...ections within a bus terminal block The electric connections between the Bus Coupler and the Bus Terminals are automatically realized by joining the components The six spring contacts of the E Bus dea...

Page 25: ...st and simple assembly High Density Terminals HD Terminals Fig 19 High Density Terminals The Bus Terminals from these series with 16 connection points are distinguished by a particularly compact desig...

Page 26: ...the screwdriver or move it alternately don t toggle 2 The wire can now be inserted into the round terminal opening without any force 3 The terminal point closes automatically when the pressure is rel...

Page 27: ...ne wire per terminal point When using fine wire conductors it is recommended to connect them with wire end sleeves in order to establish a safe conductive connection In addition make sure that the pin...

Page 28: ...not implemented 7 not implemented Uv2 8 Sensor supply Channel 2 LED Display The following table is assigned to the respective LED number of a channel Input LED Error LED Meaning off on Error detection...

Page 29: ...ig 22 ELX1054 Contact assignment Terminal point Description Designation No Input 1 1 Input Channel 1 Uv1 2 Sensor supply Channel 1 Uv3 3 Sensor supply Channel 3 Input 3 4 Input Channel 3 Input 2 5 Inp...

Page 30: ...Meaning off on Error detection open circuit on channel I 200 A typ off off Usual operation NAMUR sensor on channel in non conductive state 0 according to IEC 60947 5 6 on on Error detection short cir...

Page 31: ...t channel 2 Input 3 3 Input channel 3 Input 4 4 Input channel 4 Input 5 5 Input channel 5 Input 6 6 Input channel 6 Input 7 7 Input channel 7 Input 8 8 Input channel 8 Uv1 9 Sensor supply channel 1 Uv...

Page 32: ...on channel I 200 A typ off off Usual operation NAMUR sensor on channel in non conductive state 0 according to IEC 60947 5 6 on on Error detection short circuit on channel I 6 3 mA typ on off Usual ope...

Page 33: ...this kind of certification are marked by this sign 2 UL certification according to UL508 with limited power consumption The current consumed by the de vice is limited to a max possible current consum...

Page 34: ...of the ELX series may only be used in potentially explosive areas of Class I Division 2 Group A B C D or in non explosive areas WARNING Consider the Control Drawing ELX documentation When installing t...

Page 35: ...or Beckhoff components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 5246 963 0 Fax 49 5246 963 198 e mail info beckhoff com Beckhoff Support...

Page 36: ...segment and two ELX9410 at the end of the ELX terminal segment 19 Fig 9 Valid arrangement multiple power supplies by ELX9560 each with an upstream ELX9410 19 Fig 10 Valid arrangement ELX9410 in front...