Commissioning
EL37x2
134
Version: 3.5
Fig. 173: Variable browser up to the array VAR152
The array is then not to be opened; instead the array symbol is to be selected by right-clicking on
AddSymbol
.
Fig. 174: AddSymbol on the array
ForceOversampling
and
DataType
INT16 must be set in the channel which has now been created. If
necessary
SymbolBased
must be temporarily deactivated in addition.
Fig. 175: Channel settings
In order to check that individual oversampling values are really being logged, the
Marks
can be activated in
the Scope2. Please observe the interrelationships between task cycle time, sampling time of the Scope2
channel and oversampling factor.