Parameterization and commissioning
CX8030 / CX8031
47
Version: 1.6
http://
cx-0f94ac
/TcWebVisu/
http://
172.16.17.44
/TcWebVisu/
Ascertain before logging in (i.e. in the logged out condition) whether a ADS connection is established to the
CX – "TwinCAT Running" in the bottom right-hand corner must be green. If that is not the case, please go
onto Online/Selection of the target system again and call the CX once again.
The following path must be specified for downloading the web data for the web user interface:
\hard disk\twincat\boot\webvisu\
If that is not the case, the PLC Control will copy the data into the wrong folder and the webpage will be
displayed incorrectly or not at all.
Remote Display
This page describes the steps for remotely controlling a CE device with CE operating system from a further
PC by
‘Remote Display’
.
Software required on the PC:
• Windows NT, Windows 2000, Windows XP or Windows 7
• Microsoft Remote Display (CERHOST, available license-free from Microsoft)
Establishing the connection
The "Remote Display" tool is started on the PC. The address of the CE device can now be entered under the
menu option "File - > Connect"; this can be both the TCP-IP address or, if available, also the name of the CE
device.
If the CE device is provided with password protection, then the password must also be entered accordingly.
No password is set in the delivery condition.
After entering the target address, the user interface of the CE device is available for remote control on the
PC.
Download
: https://infosys.beckhoff.com/content/1033/cx803x_hw/Resources/zip/1608562059.zip
6.3.5
Real Time Clock (RTC)
The RTC is read out via the FB_LocalSystemTime function blocks and can be set with the NT_SetLocalTime
block (see TcUtilities.lib).
The RTC is supplied by the battery and can thus continue to run in the power-off state.