background image

Commissioning

CP32xx-2xxx-0020

17

Version: 1.1

The Panel PC is supplied automatically with the standard mounting arm adapter (1) already mounted. In
addition, you have the option to order a rotary adapter (2) under the order identifier C9900-M809. Figure 8
shows the two available mounting arm adapters.

1

2

Fig. 8: CP32xx_mounting arm adapters

The rotary adapter is mounted on the standard mounting arm adapter. To do this, follow the steps below as
shown in Figure 9:

1. Remove the two screws from the standard mounting arm adapter (Section A).

2. Place the rotary adapter between the holding brackets of the standard adapter (Section B).

3. Insert the two screws of the standard adapter again (section C).

ð

You have now mounted the rotary adapter on the standard adapter.

A

B

C

Fig. 9: CP32xx_mounting the rotary adapter

The PC is mounted rigidly on the mounting arm with the standard mounting arm adapter. With the additional
lever, the rotary adapter offers the possibility to rotate the device after mounting on the mounting arm.

Push-button extension

You have the option to order the additional C9900-M800 key extension from your Beckhoff distributor.

For explanations of the key extension, functions and assembly, refer to the associated C9900-M800 manual.

Summary of Contents for CP32 -2 -0020 Series

Page 1: ...Manual EN CP32xx 2xxx 0020 Panel PC 3 26 2021 Version 1 1...

Page 2: ......

Page 3: ...2 Mounting 16 4 2 1 Dimensions 18 4 2 2 Mounting arm installation 19 4 2 3 Mounting the keyboard shelf 21 4 2 4 Mounting the adapter housing 22 4 3 Connecting the Panel PC 22 4 3 1 Grounding the Panel...

Page 4: ...Table of contents CP32xx 2xxx 0020 4 Version 1 1...

Page 5: ...AT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered and licensed brands of Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use...

Page 6: ...ty notice will lead to death or serious injuries WARNING Disregarding the safety notice may lead to death or serious injuries CAUTION Disregarding the safety notice may lead to minor injuries Warning...

Page 7: ...ower consumption and power dissipation please refer to the respective data sheet Ensure that only trained qualified persons with a control and automation technology background operate the device Use b...

Page 8: ...r touch screen and an aluminum housing with all round IP65 protection There is an adapter on the housing for mounting arm installation on the C9900 M80x The device is available in the High Performance...

Page 9: ...ion of the Panel PC 3 Heat sink Access to the motherboard 4 Mounting arm adapter Adapter for installation on mounting arm 5 Toggle switch Switching the power supply on and off 6 Power supply XD01 Conn...

Page 10: ...rew caps from the housing see Fig 2 A B C Fig 2 CP32xx_access to interfaces 3 2 1 Power supply The Panel PC is supplied with a rated voltage of 24 V The connection of the power supply as well as the e...

Page 11: ...is a connection cable inside the column unit of the mounting arm If the Panel PC is used alone this cable is intended for the Ethernet connection of the PC If the C900 M800 key extension is also used...

Page 12: ...s provide up to 500 mA the USB 3 0 interfaces up to 900 mA They are electronically fused 1 2 3 4 5 6 9 78 1 2 3 4 5 6 9 78 1 2 3 4 5 6 9 78 1 2 3 4 5 6 9 78 Fig 5 CP32xx_USB interface pin numbering Ta...

Page 13: ...le 5 Key name plate CP32xx No Description 1 Model The last four digits indicate the device generation 2 Serial number BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Main memory 7 Hard disk 8 MAC addres...

Page 14: ...pply cable for CP32xx 2xxx length 0 75 m pre assembled Harting push pull power plug IP 65 other end Harting push pull power plug IP 65 C9900 K791 Power supply cable for CP32xx 2xxx length 0 85 m pre a...

Page 15: ...t the components are sensitive to strong vibrations and impacts During transport the device must therefore be protected from mechanical stress Appropriate packaging of the Panel PC in particular the o...

Page 16: ...options Order identifier Execution C9900 M802 Mounting arm for mounting on ceiling C9900 M803 Stand for mounting on the control cabinet C9900 M804 Stand for mounting on hall floors C9900 M805 Bracket...

Page 17: ...pter Section A 2 Place the rotary adapter between the holding brackets of the standard adapter Section B 3 Insert the two screws of the standard adapter again section C You have now mounted the rotary...

Page 18: ...ligning the device on the mounting arm All dimensions are in mm Fig 10 illustrates the dimensions of the 18 5 inch Panel PC 352 02 282 13 457 93 94 28 Fig 10 CP32xx_dimensions 18 5 inch Fig 11 illustr...

Page 19: ...0 M803 C9900 M804 and C9900 M805 mounting arms Proceed as follows to mount the Panel PC on the mounting arm 1 Remove the lower screw of the mounting arm adapter Section A 2 Hook the device into the mo...

Page 20: ...B C Fig 13 CP32xx_mounting on mounting arm variant 2 If you have chosen the rotary adapter with lever in order to be able to rotate the device on the mounting arm the installation is done in the same...

Page 21: ...key extension using the drill holes on the underside of the C9900 M800 C C A B Fig 14 CP32xx_keyboard shelf mounting options Mount the keyboard shelf directly below the PC or directly below the key e...

Page 22: ...the following point Never connect or disconnect the device cables during a thunderstorm To make the Panel PC ready for operation you have to connect it The first step is to ground the device Then you...

Page 23: ...2xxx 0020 23 Version 1 1 The EMC of the device is improved by functional earthing The functional earth is established via the grounding bolts on the mounting arm adapter Use cables with a minimum cro...

Page 24: ...HAN connection socket with the Harting HAN plug From there the voltage cables and Ethernet cables are fed through the mounting arms upwards to the opening see Figure 17 Plug the plugs protruding out o...

Page 25: ...ible voltage drop on the supply cable we recommend connecting the maximum possible cross section In the case of longer distances between the voltage source and the PC take into account the voltage dro...

Page 26: ...self afterwards If you have ordered the PC without an operating system you must install this and the driver software for the additional hardware you have connected and for the devices in the PC yourse...

Page 27: ...Panel PC during a thunderstorm can lead to electric shocks Never disconnect the cables of the of the Panel PC during a thunderstorm Before you remove the Panel PC you must follow the steps below 1 Shu...

Page 28: ...1 Remove the lower screw of the mounting arm adapter with which it is screwed to the mounting arm Section A 2 Swivel the device into an angled position so that the lower part of the mounting arm adap...

Page 29: ...er housing remove the two screws from the holding brackets with which the housing is fastened to the back of the Panel PC Disposal of the Panel PC When disposing of the Panel PC be sure to observe the...

Page 30: ...y Cleaning and maintenance by replacing certain device components contribute to this Repair Only the manufacturer may repair the device If a repair should be necessary contact Beckhoff Service see Cha...

Page 31: ...als years UPS battery pack 5 years 2 5 inch hard disk 5 years or after 20 000 operating hours at more than 40 C or after 30 000 operating hours at less than 40 C 3 5 inch hard disk 5 years irrespectiv...

Page 32: ...lly dissipating equipment and operating materials e g tools within the ESD protection zone If it is not possible to create an ESD protection zone you can still protect the device against ESD damage Th...

Page 33: ...rews section A 2 Remove the cover flap section B You now have access to the storage media A B Fig 20 CP32xx_access to storage media Access to battery and fans Access is gained to the battery and fans...

Page 34: ...Maintenance CP32xx 2xxx 0020 34 Version 1 1 1 2 Fig 22 CP32xx_battery and fans...

Page 35: ...image of your operating system and use it to back up the operating system You can then restore the images created in this way You will receive the BST on a BST stick For more information on the functi...

Page 36: ...t contain a lithium ion battery The motherboard battery is a CR2032 lithium metal cell It is used to supply power to the clock integrated on the motherboard If the battery is depleted or missing the d...

Page 37: ...3 To replace the fans follow the steps below as shown in Figure 25 1 Remove the two Torx TX10 screws from each fan to release the fans from the fan plate section A 2 Remove the fans from the fan plate...

Page 38: ...rk properly The cause of the error is the software or plant parts outside of the Panel PC Call the machine or software manufacturer The Panel PC only works partially or only temporarily e g dark image...

Page 39: ...bration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference...

Page 40: ...r which you can find on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with ot...

Page 41: ...al environment This device generates uses and may emit radio frequency energy and may cause adverse interference with radio communications if it is not installed and used in accordance with the operat...

Page 42: ...11 CP32xx_dimensions 24 inch 18 Fig 12 CP32xx_mounting on mounting arm variant 2 19 Fig 13 CP32xx_mounting on mounting arm variant 2 20 Fig 14 CP32xx_keyboard shelf mounting options 21 Fig 15 CP32xx_...

Page 43: ...in assignment 11 Table 4 USB interface pin assignment 12 Table 5 Key name plate CP32xx 13 Table 6 Power supply connection cable 14 Table 7 Ethernet connection cable 14 Table 8 Mounting arm ordering op...

Page 44: ......

Page 45: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com...

Reviews: