Product overview
CP32xx-2xxx-0020
11
Version: 1.1
3.2.2
Ethernet RJ45
The CP32xx has two Ethernet RJ45 interfaces (XF01, XF02) in the form of Harting push-pull built-in Ethernet
sockets. The 100Base-T and 1000Base-T Ethernet standards enable the connection of corresponding
network components and data rates of 100/1000 Mbit/s. The required speed is selected automatically. There
is a connection cable inside the column unit of the mounting arm. If the Panel PC is used alone, this cable is
intended for the Ethernet connection of the PC. If the C900-M800 key extension is also used in addition to
the PC, use the cable for the Ethernet connection of the key extension. For the wiring of CP32xx and C9900-
M800, a separate cable is supplied with the key extension.
8
1
8
1
Fig. 4: CP32xx_Ethernet interface pin numbering
Table 3: Ethernet interface pin assignment
Pin
Signal
Description
1
T2 +
Pair 2
2
T2 -
3
T3 +
Pair 3
4
T1 +
Pair 1
5
T1 -
6
T3 -
Pair 3
7
T4 +
Pair 4
8
T4 -