General Description
Becker Avionics
Technical Data
26
REU6100
DV64460.03 Issue 11 January 2019
Control In/Outputs
REU6100
Specifications (Discrete In/Outputs)
Control Inputs (Discrete)
Number
6
Input No.
Default Function
1
Winchman VOX-level selection
2
Intercom request activation (1600 Hz /
1200 Hz intermitted)
3
Winchman volume level selection
4
Alert tone cancellation
5
SELCALL / 3
rd
-IC-circuit activation
6
Emergency call activation (2400 Hz /
800 Hz / 1200 Hz intermitted
Activation
active LO
, ≤
1.5 V
Input current
1 mA
Control Outputs (Discrete)
Number
4
Output No.
Default Function
1
DF- blanking
2
Cockpit CALL indication
3
Cabin CALL indication
4
3
rd
-IC-circuit activation (status indication)
Switch action
active LO
Switch capability
27.5 VDC for OFF condition;
max. 500 mA in LO condition
Back-up Monitor
Number
1
Switch action
open contact
Norm Mode Output
27.5 VDC for OFF condition;
max. 500 mA in LO condition
DC-Output
DC output
27.5 VDC / 500 mA