General Description
Becker Avionics
Technical Data
28
REU6100
DV64460.03 Issue 11 January 2019
Back-up Operation
REU6100
Specifications (Back-up Operation)
Manual activation
Use the back-up switch at ACU1 or ACU2
Automatic activation
Upon supply busses failure or defection of internal
power supply or processor failure
Transceiver (radio) assignment
ACU1 - TX1, ACU2- TX2
Fixed input
ACU1 - FIX1, ACU2- FIX2
Intercom level pilot/copilot
Fixed at 50%
CVR 1and 2 level
Fixed at 50%
For REU6100-X-(3XX) variant with glass cockpit, please see related glass cockpit manual for
back-up activations and indications.
Control Data Interface REU - ACU
REU6100
Specifications (Control Data Interface REU - ACU)
Interface
CANbus
Protocol
Becker specific (Becker Bus Protocol proprietary)
Control Data Interface REU - Glass Cockpit
REU6100-X-(3XX)
Specifications (Control Data Interface REU - Glass )
Interface
RS232/422, baud rate 38400 b/s,
8 data, no parity, 1 stop bit
Protocol
Becker specific (Becker Bus Protocol proprietary)
Control Data Interface REU - REU
REU6100-X-(3XX)
Specifications (Control Data Interface REU - REU )
Interface
RS232/422, baud rate 38400 b/s,
8 data, no parity, 1 stop bit
Protocol
Becker specific (Becker Bus Protocol proprietary)
Dimensions & Weight
REU6100
Specifications
Dimensions HxWxD
195 x 57 x 338.50 mm
Dimensions depth with EM6100
379.00 mm
Weight
REU6100
≤
3 kg
Mounting tray MT519 < 0.5 kg
Case size
ATR fixture
Case material (REU6100)
AIMg