Becker Avionics
Operating Instructions
Audio Muting
DV64460.03 Issue 11 January 2019
REU6100
97
3.3 Operating
•
The REU6100 does not have any operator controls.
Operating with Becker Avionics Controller ACU610X
For detailed information refer to the manuals:
ACU6100 I&O manual (Article No. 0589.845-071)
ACU6101 I&O manual (Article No. 0614.564-071)
CSW6100 I&O manual (Article No. 0608.939-071), Software manual
(
www.becker-avionics.com/downloads/
→
Intercom).
Operating with Glass Cockpit
For detailed information refer to the manual of the respective manufacturer product manual.
3.4 Start-Up
The system DVCS6100 starts with a "Power On Built in Test" (PBIT).
•
For more details see "Build In Test Equipment (BITE)" page 27 and ACU6100/ACU6101
I&O manuals.
3.5 Headset
•
The REU6100 can operate up to six headsets with dynamic or standard microphones.
3.6 PTT Key
The standard input for the PTT activation is the ACU610X (user interface).
•
If some users have the same priority level, the priority is given to the user who first push
the Transmit-PTT (TX-PTT).
o
The-Transmit PTT has always priority over Intercom-PTT (IC-PTT).
•
The permission to use the Transmit-PTT can be individual configured for any ACU610X.
PTT Stuck Detection
•
The PTT activation to a radio stops automatically after 180 s of continuous transmission.
•
The PTT stuck detection can be enabled or disabled by the configuration setup*.
*Some adjustments of the operating parameters are only available by the configuration setup.
For more information refer to the software manual "CSW6100... " (
www.becker-avionics.com/downloads/
→
Intercom).
3.7 Audio Muting
The REU6100 can operate with unmuted intercom and transmitter reception audio during transmit
mode.
•
Monitoring of selected transmitter radios and the intercom audio during transmit mode can
be enabled or disabled by the configuration of REU6100 for any operator with ACU610X.
•