Intended use
The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This tubular drive
type is compatible with the EnOcean wireless standard and uses the profiles mentioned in the chapter "Supported profiles".
This type of tubular drive supports not only curtain attachment by means of springs but also rigid shaft connectors, such as mech-
anical anti-lifting devices manufactured by Zurfluh-Feller, Simu, GAH Alberts and Deprat. These are detected automatically.
If the springs or the top lath are screwed or riveted to the barrel, a point must be set in the lower limit position.
When mounting connection parts on the drive dia. 35 mm PXX/XX, only use screws EJOT Delta PT 40x12 WN 5454 Torx (9900 000
545 4).
For sun protection, please only use the types of tubular drive specifically designed for this purpose.
This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.
Attention
Only use rigid shaft connectors if the roller shutter laths are sufficiently strong. The closed
curtain must not project beyond the guide tracks or else there is a risk of the joint between
the top two laths being subjected to excessive strain and getting damaged.
Assembling and disassembling the plug-in connecting cable
Caution
The power supply to the connecting cable must be disconnected prior to assembly/disas-
sembly.
Assembling the plug-in connecting cable
Insert the
dead
connecting cable into the drive head until the locating lug clicks into place in the drive. If necessary, use a suitable
flathead screwdriver to assist with insertion. Set the screwdriver into one of the two plug grooves provided for this purpose.
Check that the cable is properly engaged.
1 = locating lug
6 - en