Deleting transmitters / window handles
Deleting transmitters
Put the tubular drive into programming mode.
3x
3x
<2s
Press a travel button 3 times within 2 seconds on the transmitter to be deleted.
▻
The tubular drive confirms.
►
The transmitter has now been deleted.
Deleting window handles
Put the tubular drive into programming mode.
<2s
1.
2.
Move the window handle from the CLOSED position to OPEN and back to CLOSED
within 2 seconds.
▻
The tubular drive confirms.
►
The window handle has now been deleted.
Comfort ventilation function
A prerequisite for the ventilation function is that an intermediate position II is set.
If the shading solution is below intermediate position II and a programmed window handle with EnOcean wireless technology is
turned to the "tilted" position, the shading solution moves to intermediate position II.
If the window handle is turned back to the "closed" position, the shading solution moves to the original position.
If the shading solution has been moved in the meantime and the window handle is turned to the "closed" position, the shading
solution will not move to the original position.
Lock-out protection
The lock-out protection is deactivated on delivery and can only be activated via ReMan.
If the window handle is turned to the "open" position, the down cycle is blocked.
Smoke alarm
In the event of a smoke alarm, the roller shutter moves to the upper end position and the
down cycle is blocked.
When an alarm signal is given from a programmed smoke detector, the shading solution moves to the upper end position. Smoke
detectors can only be programmed via ReMan.