Information for the electrician
Use external conductor L1 to control the up and down direction. Other devices or consumers (lamps, relays, etc.) must not be dir-
ectly connected to the drive connecting cables. For this purpose, the drives and additional devices must be decoupled by relay
controls.
When installing the drive, all-pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided.
Attention
Only use mechanically or electrically locked switching elements with a marked zero posi-
tion! This also applies when drives with electronic and mechanical limit switching are used
in the same system. The changeover time for switching the running direction must be at
least 0.5 s. The switch and control unit must not execute simultaneous UP and DOWN com-
mands. Protect the electrical connections from damp.
Once you have finished wiring everything to the control unit, ALWAYS check the correct as-
signment of the drive running direction to the control buttons UP and DOWN, EXTEND and
RETRACT.
If the drive is to be operated with devices which contain sources of interference, the elec-
trician must ensure suitable interference suppression for the relevant devices.
Torque detection
A correctly installed tubular drive reacts to extraordinarily large increases in load during operation between the limit positions and
thereby prevents an overload of the tubular drive.
Move to the opposite limit position to reference the limit positions again.
Disposal
This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc-
ling or disposal for this product in your country.
The packaging material must be disposed of properly.
Maintenance
These drives are maintenance-free.
Technical data dia. 45
Tubular drive
R40-17
Model
E25
Type
HK R
Rated torque [Nm]
40
Output speed [rpm]
17
Limit switch range
64 revolutions
Supply voltage
230 V AC / 50 Hz
Connected load [W]
260
Rated current consumption [A]
1.15
Operating mode
S2 4 min
Degree of protection
IP 44
Min. tube inside diameter [mm]
47
Emission sound pressure level [dB(A)]
≤ 70
15 - en