Clean the device with a damp cloth only. Do not use a cleansing agent as this
may damage the plastic.
Technical data
Cleaning
Nominal voltage
230240 V AC / 5060 Hz
Switched current
5 A /250 V AC for cos
ϕ
=1
System of protection
IP 20
Protection class
II In accordance with the assembly
specifi cations
Permissible ambient temperature
0 to +55 °C
Running time awning
2 min
Running time Venetian blinds
3 min
Type of installation
Concealed Ø 58 mm wallmounted.
Exposed in appropriate exposed casing.
What to do if...?
Problem
Cause
Remedy
Drive is not functioning. Faulty connection.
Check connection.
Blind or shutter moves
in the wrong direction.
Faulty connection.
Exchange
and
wires
in the power supply unit.
The UCS520 does not
carry out the external
commands.
The UCS520 is in manual
mode.
Set the UCS520 to auto-
matic mode.
Manual commands are
not executed.
The alarm signal is on.
Wait until the alarm signal
disappears or switch
it off.